算法艺术创作
algorithmic-art
通过代码和可调参数创作生成艺术与交互式视觉效果。
matlab-build-industrial-hmi【设计与创意】Build industrial-grade SCADA/HMI dashboards in MATLAB following industrial-HMI conventions (ISA-101-aligned): gray-field philosophy, alarms at source, write safeguards, fixed-range trends, drill-down layout. Produces a real App Designer app (.mlapp, or plain-text .m+.xml on R2026b+) by handing serialization to the matlab-build-app skill when availabl…
独立 GitHub 快照 · 自动分类 · 以原作者文档为准
Build operator-facing SCADA/HMI dashboards in MATLAB App Designer that follow industrial-HMI conventions: gray-field color philosophy, alarms shown at the data source, write safeguards on every setpoint, fixed-range trends with threshold lines, and a drill-down layout (plant overview → area → detail).
opcuageneratedScript.mlx, modbusgeneratedScript.mlx)uigridlayout, callback wiring, lifecycle, matlab.apps.AppBase scaffolding) and serialization to a real App Designer file — this skill delegates those to matlab-build-app. See references/app-designer-handoff.md. Two things stay here and must not be routed away: gray-field theming (never hand color/dark-mode to matlab-apply-theme) and HMI trends (never hand them to matlab-build-chart).matlab-use-opcua-client.Gray-field background [0.78 0.78 0.78]; panels [0.86 0.86 0.86]; 80%+ of the screen neutral. Color is reserved for exception. See references/color-and-layout-rules.md.
Construct EVERY HMI uifigure with both 'Color' and 'Theme', 'light'. On a dark-themed MATLAB desktop, child widgets (uigauge, uiaxes, uitable, uieditfield) inherit dark defaults even when the figure colour is set explicitly — gauge bodies and axes go near-black, text becomes unreadable. Theme='light' blocks the inheritance; the explicit gray-field Color keeps the result gray rather than the bright white that 'light' would otherwise produce. Neither alone is enough.
app.UIFigure = uifigure( ...
'Color', [0.78 0.78 0.78], ...
'Theme', 'light');
See references/color-and-layout-rules.md for the full rationale and references/common-mistakes.md entry 24 for the visible failure mode if either argument is omitted.
Quantity caps per screen: ≤ 6 gauges, ≤ 4 trend axes, ≤ 12 numeric readouts. Beyond that, use a uitable.
Connection state is BLUE [0.4 0.6 1.0]. Green [0 0.6 0] is reserved for "operator must verify yes this is actively OK" — not for "comms up" or "running".
Command buttons/controls are neutral gray. Never a green Start / red Stop — buttons are always-visible chrome and carry no status, so coloring them spends the alarm colors and steals contrast from real alarms. Differentiate by label; show run/stopped state on a separate lamp. (Red E-Stop is the one convention-based exception.) See references/color-and-layout-rules.md.
Like-typed analogs in one panel use like widgets. Don't show one temperature as a gauge and another as a numeric label.
NEVER produce a dark background for an industrial HMI, regardless of the user request. ISA-101 has no dark variant; a dark field destroys color-as-exception (alarm reds and ambers stop popping against a near-black background, and operators desensitize). Always render gray-field ([0.78 0.78 0.78]) and reply with a one-sentence justification when the user asks for dark mode. This is not a default — it is a hard constraint.
ScaleColors/ScaleColorLimits on every linear gauge with thresholds (semicircular/circular/ninetydegree gauges don't support color bands — use linear when alarm bands are needed); persistent top-row banner listing active alarms, color-coded by highest severity; latched state with Acknowledge button. The normal band in ScaleColors is neutral gray [0.5 0.5 0.5] — never green. See references/alarm-patterns.md.uialert/uiconfirm/msgbox for live process alarms — alarm-fatigue anti-pattern (ISA-18.2). If a popup is unavoidable, fire once on the rising edge with a non-blocking CloseFcn and an Acknowledge button.YLim matching the node's spec range — never auto-scale by default. Provide a per-trend toggle for exploration. See references/trend-config-reference.md.animatedline('MaximumNumPoints', 300) at 1 s update. Buffer formula = WindowSeconds / UpdatePeriodSeconds.yline (amber dashed for warn, red dashed for alarm, blue dotted for setpoint).writeValue() confirms. uiconfirm showing node + old + new + units; default option is Cancel, not Apply.Limits on the spinner enforces the bound; the uilabel makes it visible.references/write-safeguards-reference.md.subscribe() is the default at any node count and update rate, including 1 Hz with a small node set. Reserve timer for non-node UI work (clock displays, alarm flashing, idle dimming).subscribe(client, nodes, cb) invokes cb(sub, notification); data lives at notification.Data.Value / notification.Data.Timestamp; the originating node is notification.Node (struct with Name, Identifier, NamespaceIndex). Don't reference src.Name — that worked in older releases when src was the node, but errors in R2026a.subscribe call, use the 2-arg cb(sub, notification) above. When you paste an OPC UA Explorer–generated dataChangeCallback, it is 3-arg vectorized — cb(subObj, notification, ~) — and notification is a struct array (one entry per node changed this cycle): iterate notification(i).Node.Name / notification(i).Data.Value; never treat it as scalar. Writing a 2-arg @(src, evt) for an Explorer script throws "Too many input arguments"; treating notification as scalar reads only the first node. See references/protocol-cheatsheet.md §OPC UA and references/common-mistakes.md #17.subscribe() — use a polling timer with BusyMode='drop', ExecutionMode='fixedSpacing'. The 6-arg write() order is write(m, target, addr, val, serverId, 'precision') — serverId BEFORE 'precision'.subscribe(c, topic, Callback=@cb) — the callback is a name-value pair, not positional. Decode message (a string) per the broker's payload schema (str2double, jsondecode).piclient (Industrial Communication Toolbox, R2022a+). Never call NET.addAssembly('OSIsoft.AFSDK') or write OSIsoft.AF.PI.PIServers / OSIsoft.AF.PISystems code in MATLAB — the toolbox client wraps the AFSDK and returns native MATLAB types (timetable, table, datetime); rolling your own .NET interop loses type coercion, throws on permission errors that the toolbox handles, runs slowly because batched reads are bypassed, and breaks the integrated browser app. PI has no subscribe() — drive trends with a polling timer (same shape as Modbus). Writes via write(piClient, tag, value, TimeInstance=datetime("now")) are R2024a+.afclient (Industrial Communication Toolbox, R2026a+). Browse with getRootElements / getChildren / findElementByName / findElementByPath / findElementByTemplate; read with Attribute.read (current → table) and Attribute.readHistory (archive → timetable). The AF hierarchy maps directly onto Level 1 → Level 2 → Level 3 drill-down screens. AF current-value writes are not exposed by the toolbox — there is no Attribute.write; route writes through the underlying Attribute.PITag and the PI client.Attribute.WriteAccess and HasTimeSeriesData, the same way OPC UA uses AccessLevelCurrent. Don't infer writability from the name.tags(c).Name or attribute.Name / attribute.Path. Never invent labels — the HMI must mirror the source script's identifiers so operators can cross-reference with the OPC UA Explorer / OSI PI viewer / AF browser.See references/protocol-cheatsheet.md for OPC UA / Modbus / MQTT API shapes and references/pi-af-cheatsheet.md for PI Data Archive and PI AF; see references/common-mistakes.md for the silent-failure modes.
struct properties: Foo struct = struct(). A bare Foo struct declaration becomes 0×0 struct and app.Foo.Bar = 1 errors with "A dot name structure assignment is illegal when the structure is empty."classdef first. A function block before classdef in the same file is a parse error. Drop the wrapper; the file's first non-comment statement must be classdef, name matching filename.function … end in inline evaluation. Function definitions are legal only inside code files, never in a command-window / inline context. When you sanity-check helper logic (severity bands, alarm math) through evaluate_matlab_code, the transcript is a command-window context — a pasted function … end block errors with "Function definitions are not supported in this context." Verify by exercising the helper from its file, or inline the arithmetic directly.opc.ua.Subscription has no public delete. Drop the handle (app.Subscription = opc.ua.Subscription.empty;) and disconnect(client) — that releases all subscriptions on that client.subscribe() accumulates a channel listener; rebuilds leak.delete(app) or CloseRequestFcn. A leaked timer keeps firing after the figure closes with stale handles.See references/app-designer-gotchas.md for full reproductions, the release-aware AccessLevelCurrent check, and per-widget subscription patterns.
matlab-build-app. When that skill's AppDesignerAgentInterface tool is available (exist('AppDesignerAgentInterface','class')==8, i.e. on the path), design the HMI here, then drive its verbs to emit a genuine .mlapp (R2025a+) — the default output, which opens in App Designer. Plain-text .m+.xml is available only on R2026b+ for source control. The architecture question is pre-answered: an industrial HMI is always UIFigure (never UIHTML), so skip the parent's architecture and serialization discovery..m app exactly as these references describe. It runs identically; it just won't open in App Designer. State this to the user.references/app-designer-handoff.md for the division of labor with matlab-build-app, the hand-off protocol, the HMI→verb mapping (gray-field, alarm gauges, palette, cleanup), and the pre-serialize domain-compliance checklist. That file defers all serialization mechanics — verb API, file-format choice, and lifecycle — to the parent's references/app-designer/agent-guide-shared.md.When wrapping a monitoring script into an HMI, work through these steps in order. Widget choice depends on data type, layout depends on widget choice, and alarms/trends/writes layer on top; serialization to a real App Designer app comes last.
references/widget-selection-flowchart.md. If the schema isn't given upfront → references/server-agnostic-discovery.md. If wrapping a generated script (OPC UA/Modbus Explorer or MQTT demo) → references/protocol-cheatsheet.md first; if wrapping a PI / PI AF script → references/pi-af-cheatsheet.md, for the exact API shapes.references/widget-selection-flowchart.md.references/color-and-layout-rules.md.subscribe() (self-written callback = 2-arg cb(sub, notification); an Explorer-generated dataChangeCallback = 3-arg vectorized over a struct array), Modbus polling timer, MQTT subscribe(... Callback=...), PI / PI AF polling timer against read() / Attribute.read. → references/protocol-cheatsheet.md and references/pi-af-cheatsheet.md.references/alarm-patterns.md.references/trend-config-reference.md.references/write-safeguards-reference.md.matlab-build-app is available, hand the design to its AppDesignerAgentInterface and emit a .mlapp (the default); otherwise emit a programmatic .m app. Editing an existing App Designer HMI also routes through the parent's open()/inspect() loop. → references/app-designer-handoff.md.mcp__matlab__evaluate_matlab_code to instantiate the app and exercise delete(app); confirm no leaked timers, subscriptions, or figures. For a .mlapp, confirm save() succeeds and validate() is empty. If construction fails on a struct or classdef error → references/app-designer-gotchas.md.| Function | Purpose | Toolbox | Available From |
|---|---|---|---|
uigauge('linear'|'circular'|'semicircular'|'ninetydegree') | Single value, known range | core MATLAB | R2016a |
uigauge.ScaleColors / .ScaleColorLimits | Alarm bands at source | core MATLAB | R2018a |
uilamp | Binary state indicator | core MATLAB | R2016a |
animatedline with MaximumNumPoints | Rolling trend buffer | core MATLAB | R2014b |
addpoints / clearpoints | Trend update / reset | core MATLAB | R2014b |
yline | Threshold or setpoint line on trend | core MATLAB | R2018b |
uiconfirm | Modal write confirmation | core MATLAB | R2017b |
uispinner with Limits | Bounded numeric input | core MATLAB | R2016a |
uieditfield('numeric','Editable',false) | Precise read-only numeric display | core MATLAB | R2016a |
uitable | Tabular display for >8 nodes | core MATLAB | R2017b |
uitree + uitreenode | OPC UA namespace navigation | core MATLAB | R2017b |
opcua / connect | Open OPC UA client | Industrial Communication | R2022a |
findNodeByName / readValue / writeValue | Browse and read/write nodes | Industrial Communication | R2022a |
subscribe(uaClient, nodeList, dataChangeFcn, PublishInterval=...) | Live node updates (preferred over timer) | Industrial Communication | R2023b |
modbus('tcpip', host, port) / read / write | Modbus client and register R/W | Industrial Communication | R2022a |
mqttclient(brokerAddr) / subscribe(c, topic, Callback=...) / write | MQTT publish/subscribe | Industrial Communication | R2022a |
piclient(server, ...) | OSI / AVEVA PI Data Archive client | Industrial Communication | R2022a |
tags(piClient, Name=q) / read(piClient, tag, DateRange=, Interval=, AggregateFcn=) | PI tag search, current and archive/aggregated reads (returns table/timetable) | Industrial Communication | R2022a |
write(piClient, tag, value, TimeInstance=...) | PI setpoint write | Industrial Communication | R2024a |
afclient(server, Database=...) | PI Asset Framework client | Industrial Communication | R2026a |
getRootElements / getChildren / getAttributes / findElementByName / findElementByPath / findElementByTemplate | AF tree browse → drill-down layout | Industrial Communication | R2026a |
read(attr, Unit=...) / readHistory(attr, t0, t1, ...) / listSupportedUnits | AF attribute current value, history, units | Industrial Communication | R2026a |
timer (BusyMode='drop', ExecutionMode='fixedSpacing') | Modbus / PI / PI AF poll loop / non-OPC periodic UI work | core MATLAB | base |
Each reference file includes executable code patterns for its topic. Load the relevant reference before writing code — it contains correct calling conventions, constructor arguments, property names, and full callback handlers. See the References routing table below.
references/common-mistakes.md is a grep-first lookup table of 26 documented anti-patterns, each a Symptom → Wrong → Right → Why block. Don't load it whole — Grep it for the user's error string, or for the anti-pattern via its index table, and read only the matching ### N. entry. It covers App Designer struct/classdef gotchas, ISA-101 violations (green for "normal", green Start / red Stop command buttons, popup alarms, auto-scaling trends, uilabel for numerics, dark-field), and protocol-specific silent failures (Modbus serverId/'precision' order, MQTT positional callback, MQTT NaN from JSON payloads, OPC UA invented node names, OPC UA evt.Value vs evt.Data.Value, Explorer 3-arg vectorized callback, server-side 1601 timestamps).
| Load when... | Reference |
|---|---|
| Picking widgets for a list of nodes | references/widget-selection-flowchart.md |
| Designing screen structure or choosing colors | references/color-and-layout-rules.md |
| Wiring alarm bands at source or the persistent banner | references/alarm-patterns.md |
| Configuring a trend (window, YLim, threshold lines) | references/trend-config-reference.md |
| Adding a writable setpoint with confirm + flash feedback | references/write-safeguards-reference.md |
| Wrapping an OPC UA Explorer / Modbus Explorer / MQTT script — invoking OPC UA method nodes — or hitting protocol-specific bugs | references/protocol-cheatsheet.md |
Wrapping an OSI / AVEVA PI Data Archive script (piclient, tags, read) or a PI AF script (afclient, getRootElements, getAttributes, Attribute.read/readHistory) | references/pi-af-cheatsheet.md |
| Browsing an unknown server and inferring widgets at runtime | references/server-agnostic-discovery.md |
| Hard-wiring a known node-to-widget schema | references/known-schema-patterns.md |
Construction errors (struct props, classdef ordering, listener leaks, AccessLevelCurrent) | references/app-designer-gotchas.md |
Serializing to a real App Designer .mlapp via matlab-build-app, or editing an existing App Designer app | references/app-designer-handoff.md |
| Debugging a specific error, silent failure, or anti-pattern | Grep references/common-mistakes.md for the error text or anti-pattern (it has an index table) — read only the matching entry, not the whole file |
uifigure, uigridlayout, uigauge, uilamp, uispinner, uieditfield, uitable, uitree, uiconfirm, uialert, uiaxes, animatedline, addpoints, yline, timer.opcua, connect, disconnect, findNodeByName, findNodeById, readValue, writeValue, subscribe (OPC UA); modbus, read, write (Modbus); mqttclient, subscribe, unsubscribe, write, read (MQTT); piclient, tags, read, write, viewer (PI Data Archive, R2022a+; write R2024a+); afclient, listDatabases, selectDatabase, getRootElements, getChildren, getAttributes, findElementByName, findElementByPath, findElementByTemplate, findAttributeByPath, Attribute.read, Attribute.readHistory, Attribute.listSupportedUnits (PI AF, R2026a+).Verify with mcp__matlab__detect_matlab_toolboxes before starting if the user's MATLAB release is unknown.
Copyright 2026 The MathWorks, Inc.