界面已本地化;技能介绍与说明文档按所选语言由 AI 自动翻译,代码、命令、路径和专业术语保留原文,以原作者文档为准。
探索技能
设计与创意 · SKILL.md

aedt-evidence-electromagnetics

aedt-evidence-electromagnetics

【设计与创意】Evidence-first Ansys Electronics Desktop and PyAEDT automation for Maxwell, HFSS, Q3D, Icepak, and related electromagnetic workflows. Use when Codex must check AEDT/PyAEDT, create or run a real AEDT design, verify the selected design and solution type, extract fields or matrices, export an .aedt project, or distinguish direct PyAEDT work from an AEDT…

独立 GitHub 快照 · 自动分类 · 以原作者文档为准

技能说明

GitHub

name: aedt-evidence-electromagnetics description: Evidence-first Ansys Electronics Desktop and PyAEDT automation for Maxwell, HFSS, Q3D, Icepak, and related electromagnetic workflows. Use when Codex must check AEDT/PyAEDT, create or run a real AEDT design, verify the selected design and solution type, extract fields or matrices, export an .aedt project, or distinguish direct PyAEDT work from an AEDT MCP bridge.

AEDT Evidence Electromagnetics

Use the repository toolbox and a user-owned AEDT installation. Never infer a successful electromagnetic solve from ansysedt.exe, a project file, or a geometry screenshot.

Start

ai-cae-toolbox context-scope --solver aedt
ai-cae-toolbox bridge-plan --solver aedt --objective "<objective>"
ai-cae-toolbox create-run --solver aedt --case <case-name> --objective "<objective>"
ai-cae-toolbox write-smoke-template --solver aedt --run-dir <run-dir>

If MCP is available, prefer:

  • aedt_check_installation
  • aedt_run_pyaedt_script_file
  • scan_run_evidence
  • generate_run_report

Select the Correct Route

  • Use direct PyAEDT when the requested solver or API surface is not exposed by the installed MCP.
  • Use an AEDT MCP only for capabilities it actually exposes.
  • Do not build HFSS when the task requires Maxwell, or claim that an HFSS-focused MCP completed a Maxwell workflow.
  • Record AEDT version, PyAEDT version, project, design name, design type, solution type, and whether a new or existing desktop session was used.

Execute

Keep scripts in scripts/, source parameters in inputs/, project outputs in outputs/, and field plots/tables in exports/. Make every geometry dimension, material, excitation, boundary, setup, and sweep explicit.

For Maxwell matrix work, audit winding polarity and reciprocity. For HFSS, audit ports, modes, radiation boundaries, frequency setup, adaptive convergence, and S-parameter passivity. Read references/acceptance-gates.md before interpreting solver output.

Finish

Collect the AEDT project, solver/adaptive log, mesh statistics, numeric CSV/JSON, field images, and a report. Clearly label any external circuit calculation or Python-derived plot that is not a native AEDT result.

ai-cae-toolbox scan-evidence <run-dir>
ai-cae-toolbox generate-report <run-dir>
我的收藏