界面已本地化;技能介绍与说明文档按所选语言由 AI 自动翻译,代码、命令、路径和专业术语保留原文,以原作者文档为准。
探索技能
设计与创意 · SKILL.md

advmat-methods

advmat-methods

【设计与创意】Use when deciding what characterization and experimental detail an Advanced Materials manuscript must show to prove its structure–property claim, and what belongs in the Experimental Section and Supporting Information. Partitions and stress-tests methods; does not design figures or run analysis.

独立 GitHub 快照 · 自动分类 · 以原作者文档为准

技能说明

GitHub

name: advmat-methods description: Use when deciding what characterization and experimental detail an Advanced Materials manuscript must show to prove its structure–property claim, and what belongs in the Experimental Section and Supporting Information. Partitions and stress-tests methods; does not design figures or run analysis.

Advanced Materials Methods & Characterization (advmat-methods)

When to trigger

  • Your structure or phase assignment rests on a single technique
  • A reviewer of a prior draft asked "how do you know it is this phase / this mechanism?"
  • The device metric has no benchmarking against comparable state-of-the-art systems
  • The Experimental Section sprawls, or you cannot tell what belongs in the body vs. the SI
  • Reproducibility is thin: batch-to-batch spread, synthesis provenance, or statistics are missing

The multi-technique principle

An Adv. Mater. claim about a material must be triangulated by complementary techniques, not asserted from one. A single XRD pattern or one TEM image is rarely enough; referees expect the structure–composition–property picture to close from several independent angles.

A practical characterization matrix (adapt to your material class):

Claim you are makingDo not rely on one technique — triangulate with
Crystal structure / phaseXRD (+ Rietveld) and electron diffraction (SAED) / HRTEM lattice
Morphology / size / architectureSEM and TEM (+ statistics over many particles, not one hero image)
Composition / oxidation stateXPS and EDS/EELS mapping and ICP-MS/AES for bulk stoichiometry
Local bonding / defectsRaman / FTIR / XAS (XANES/EXAFS), NMR where applicable
Optoelectronic propertyUV-vis / PL / TAS + the transport or device measurement it predicts
Electrochemical performanceCV + galvanostatic cycling + rate/stability data + post-mortem analysis

State uncertainties and sample counts. "n = 3 devices, mean ± s.d." beats a single best cell.

Benchmarking is not optional

Adv. Mater. device claims live or die on fair comparison to the state of the art. Put the comparison in the paper, on equal footing:

  • Compare against the best reported systems for the same function, under comparable conditions — cite them.
  • Report the metric with its measurement protocol (scan rate, illumination, active area, humidity) so it is comparable.
  • If you claim a record, show a benchmark table or plot (e.g. an efficiency-vs-stability or Ragone-style comparison) rather than a bare number.

Body vs. Experimental Section vs. Supporting Information

Detail typeMain text / Experimental SectionSupporting Information
Core synthesis route + key parametersExperimental Section (reproducible)full optimization sweeps
The decisive characterization proving the claimmain-text figureextended datasets, more samples
Device fabrication + measurement protocolExperimental Sectionfull protocols, control devices
Benchmarking vs. state of the artmain textfull comparison table + refs
Statistics on the headline metricmain text (n, mean ± s.d.)per-sample data, histograms
Instrument models / settingsExperimental Section (concise)exhaustive parameters

The Experimental Section must let a competent group reproduce the material. Detail that is essential-but-bulky (full recipes, calibration, secondary controls) goes to the SI and is cited inline.

Rigor without bulk

  • Pre-empt the leading alternative explanation for your structure/property claim in the body, briefly, and point to the SI for the exhaustive checks.
  • Report purity/phase fraction, not just "phase-pure" as an adjective.
  • Give data-availability and, where relevant, computational details (see resources/external_tools.md for the DFT/simulation stack).

Checklist

  • Every structural/compositional claim is supported by ≥2 complementary techniques
  • Morphology/size claims carry statistics, not a single hero image
  • The headline metric is benchmarked against cited state-of-the-art systems, fairly
  • Device metrics report the full measurement protocol (area, conditions, scan rate)
  • The headline number carries a sample count and spread (n, mean ± s.d.)
  • The Experimental Section is reproducible; bulky detail is in the SI and cited
  • The leading alternative explanation is named and addressed

Anti-patterns

  • A single-technique structure claim ("XRD confirms the phase") with no corroboration
  • One flattering TEM/SEM image standing in for a distribution
  • A record metric with no benchmarking and no measurement conditions
  • Reporting one best device and hiding batch-to-batch variability
  • An Experimental Section too vague to reproduce, or so long it belongs in the SI
  • "Data available on request" instead of a concrete availability statement

Output format

【Central material claim】...
【Triangulation】technique 1 / technique 2 / technique 3 — sufficient?  yes / add: ...
【Morphology statistics】present?  yes / fix
【Benchmarking vs. SOTA】in main text, fair, cited?  yes / fix
【Metric statistics】n + spread stated?  yes / fix
【Reproducibility】Experimental Section reproducible?  yes / fix
【Next】advmat-figures (characterization figure) or advmat-supplementary (SI partition)

Data-availability, reproducibility, and characterization-reporting expectations evolve — verify current Wiley Advanced Materials policy on the official author page.

我的收藏