算法艺术创作
algorithmic-art
通过代码和可调参数创作生成艺术与交互式视觉效果。
country-japan【设计与创意】Japan architectural code and regulatory reference. Covers the Building Standards Act (Kenchiku Kijun Ho, 1950, fundamentally revised 1998 toward performance-based regulation and 2007 strengthening post-Aneha incident), Building Standards Law Enforcement Order (Kenchiku Kijun Ho Shiko Rei) and MLIT Notifications (Kokuji); the parallel Fire Service Act…
独立 GitHub 快照 · 自动分类 · 以原作者文档为准
Architectural code and regulatory reference for projects in Japan (all 47 prefectures + Tokyo Metropolis). Activate this skill on any Japanese city/prefecture reference, JPY currency, mention of "Kenchiku Kijun Ho"/"BSL"/"Sho-Energy Ho"/"CASBEE"/"AIJ"/"BCJ"/"Shintaishin", or Japanese architectural terminology (yoseki-ritsu, kenpei-ritsu, kakunin-shinsei, kanseikensa, joryoku-do, koshou-tatemono, mokuzo).
Japan operates as Archetype D (Centralised National + Strong-Form Clauses). Building regulation is national, administered through prefectures + designated cities under Building Standards Act delegated authority. Some matters are devolved to designated cities.
LEVEL 1 -- NATIONAL
Ministry of Land, Infrastructure, Transport and Tourism (MLIT, Kokudo Kotsu Sho)
Housing Bureau (Jutaku Kyoku) -- residential policy
City Bureau (Toshi Kyoku) -- urban planning
Land and Real Estate Industry Bureau
+ issues MLIT Notifications (Kokuji) -- detailed technical requirements
Ministry of Internal Affairs and Communications (Somu Sho) -- Fire Service Agency
Ministry of Health, Labour and Welfare (Kosei Rodo Sho) -- hospital regulations
Ministry of Economy, Trade and Industry (METI, Keizai Sangyo Sho) -- energy + product safety
Ministry of the Environment (Kankyo Sho) -- environmental
Ministry of Education (MEXT) -- school facilities
National Police Agency -- some safety regulations
LEVEL 2 -- PREFECTURE (todofuken) + DESIGNATED CITIES
47 prefectures + 20 Designated Cities (Seirei Shitei Toshi) -- e.g.,
Tokyo (special category as Metropolis), Osaka, Yokohama, Nagoya, Sapporo, Kobe,
Kyoto, Fukuoka, Hiroshima, Sendai, Kawasaki, Saitama, Chiba, Niigata, Hamamatsu,
Sakai, Shizuoka, Okayama, Sagamihara, Kumamoto
Tokutei Gyousei Cho (Designated Administrative Officer) -- typically prefectural or
designated-city housing department; oversees Kakunin-shinsei (building confirmation)
Building Examiners (Kenchiku Shujikan) -- public officials
Designated Confirmation Inspection Agencies (Shitei Kakunin Kensa Kikan) -- private
since 1998 reform; competitive choice
LEVEL 3 -- MUNICIPALITY (shi-cho-son)
Smaller cities, towns, villages -- if not Designated City, defer to prefecture for building
confirmation but handle planning under City Planning Act
Local Fire Departments (Shobosho)
LEVEL 4 -- PROJECT
Kakunin-shinsei (Building Confirmation Application) submitted by Class 1 Architect or
qualified delegate
Structural calculations checked: (a) self-check up to threshold (BCJ-evaluated etc.),
(b) Performance Evaluation by accredited body (BCJ, Japan Engineering Standards
Foundation, etc.) for taller/special buildings
Periodic inspection during construction (Kanseikensa)
Article 7 Inspection (kansei kensa) -- final inspection before occupancy
The Building Standards Act 1950 (BSA) was fundamentally reformed in 1998 (introducing performance-based regulation) and amended again in 2007 (post-Aneha falsified structural calculations scandal, which strengthened independent structural review).
Structure:
Tokyo Metropolitan Government (Tokyo-to) has 23 special wards (Tokubetsu-ku) functioning as municipalities + the multi-city Tama region. Building confirmation in Tokyo's 23 wards is generally handled by the Tokyo Metropolitan Government Bureau of Urban Development + ward offices for smaller works. Tokyo has its own Tokyo Metropolitan Ordinance on Building Standards -- supplements BSA.
BSA classifies buildings by use + structure + scale:
| Use Category | Description |
|---|---|
| Tokushu Kenchikubutsu | Special Buildings -- assembly, hospital, school, hotel, etc.; many require BCJ structural eval, additional fire requirements |
| Ippan Kenchikubutsu | General Buildings -- offices, factories |
Special structures (high-rise, large span, special concrete) require BCJ structural performance evaluation per BSA Article 20 + sub-clauses.
The two principal Japanese density controls:
| Use District | Yoseki-ritsu Range | Kenpei-ritsu Range | Use |
|---|---|---|---|
| First Class Low-rise Residential (Daiichi-shu Tei-so Jukyo) | 50-200% | 30-60% | Houses ≤10/12 m height |
| Second Class Low-rise Residential | 50-200% | 30-60% | Similar +small shop |
| First Class Mid/High-rise Residential | 100-500% | 30-60% | Apartments + small commerce |
| Second Class Mid/High-rise Residential | 100-500% | 30-60% | + medium retail |
| First Class Residential | 100-500% | 50-80% | Residential + offices/retail moderate |
| Second Class Residential | 100-500% | 50-80% | + entertainment limited |
| Quasi-Residential | 100-500% | 50-80% | Roads + residential mix |
| Neighbourhood Commercial | 200-500% | 60-80% | Shops + service |
| Commercial | 200-1300% | 80% | Full commerce + tall buildings |
| Quasi-Industrial | 100-500% | 50-80% | Light industrial |
| Industrial | 100-400% | 50-60% | Factory mix |
| Exclusively Industrial | 100-400% | 30-60% | Heavy industry only |
| Field of Tanada | (rural special) | -- | Agricultural |
A particularly Japanese set of regulations:
These controls collectively shape Japanese urban form -- often producing characteristic "stepped" or "wedding cake" massing.
BSA Article 20 sets four tiers of structural review:
Tier 1 cases: building > 60 m, or special types (seismic isolation building, special structural performance like FRPs, ultra-light long-span etc.)
| Parameter | Sprinklered | Unsprinklered |
|---|---|---|
| Max travel distance (general) | 50 m | 30 m |
| Max travel distance (assembly, dormitory) | 40 m | 30 m |
| Max travel distance (hospital, ROS-protected) | 50 m | 30 m |
| Min corridor width (Special Buildings >= 200 m2/floor) | 1.6 m double-loaded; 1.2 m single | -- |
| Min corridor width (residential each floor) | 1.2 m double-loaded; 0.9 m single | -- |
| Min stair width (Special Buildings >= 200 m2/floor) | 1.4 m | 1.4 m |
| Min stair width (residential >= 600 m2 total) | 1.2 m | 1.2 m |
| Min door clear width | 800 mm (Special Buildings); 750 mm (general) | -- |
Two means of escape required when:
The defining feature of Japanese structural design. Building must be safe under:
The 1981 revision (Shintaishin -- "New Earthquake-Resistance Standard") introduced this two-level approach. Buildings built before 1981 are designated "Kyu-taishin" and many have been retrofitted.
Japan ground classes (BSA Enforcement Order Article 88):
Japan uniquely operates fire safety under two statutes:
Plans must be approved by both Designated Administrative Officer (BSA) and Fire Department (FSA).
Fire-resistance hours:
Japan emphasizes outside-air stair (To-no-zen Kaidan) -- stairs vented to outside, often via open balcony. Provides smoke-free escape route without requiring positive pressurization.
For tower buildings without external stair access, smoke-resistance compartments (To-no-zen Shitsu) are provided -- lobby + stair both pressurized or vented.
Hospitals, fire stations, government emergency operations centres, designated evacuation centres designed for post-event functionality -- structural drift limits tighter, redundancies for utilities, separate emergency power.
Replaced the older Energy Conservation Act 1979 for buildings. Mandatory compliance for:
Compliance demonstrated via:
Japan defines 8 climate zones (Region 1 through Region 8) based primarily on HDD (heating degree days):
| Zone | Approximate Region | Typical Cities |
|---|---|---|
| Region 1 | Sub-arctic | Hokkaido east + interior (Asahikawa, Kushiro) |
| Region 2 | Cold | Hokkaido west + Tohoku interior (Sapporo, Aomori interior) |
| Region 3 | Cool-cold | Tohoku coast + Hokuriku (Sendai, Akita, Niigata) |
| Region 4 | Cool | Inland Honshu (Nagano interior, Saitama interior) |
| Region 5 | Temperate | Tokyo, Yokohama, Osaka -- main urban regions |
| Region 6 | Mild | Western Honshu, Shikoku (Hiroshima, Takamatsu, Fukuoka) |
| Region 7 | Warm | Southern Kyushu (Kagoshima) |
| Region 8 | Subtropical | Okinawa |
| Zone | UA (W/m2K) max | ηA (avg solar) max |
|---|---|---|
| 1 | 0.40 | -- |
| 2 | 0.40 | -- |
| 3 | 0.50 | -- |
| 4 | 0.60 | -- |
| 5 | 0.87 | 3.0 |
| 6 | 0.87 | 2.8 |
| 7 | 0.87 | 2.7 |
| 8 | -- | 6.7 (cooling-dominated) |
(UA = average U-value over external envelope; ηA = average solar acquisition factor)
METI subsidies tied to these tiers.
Japan's own green building assessment system, comparable to LEED + DGNB. Rates by:
Many municipalities require CASBEE B+ or A as minimum for medium-large buildings.
Act on Promotion of Smooth Transportation of Elderly, Disabled Persons (2006) -- consolidated previous Heart Building Law + Traffic Barrier-Free Law.
Mandatory provisions for:
| Element | Dimension |
|---|---|
| Accessible route | 1.2 m (1.5 m preferred); passing space 1.4 x 1.4 m every 50 m |
| Door clear width | 800 mm |
| Ramp gradient | 1:12 max; landings every 6 m run + at top/bottom |
| Lift cabin | 1100 x 1350 mm (Type 1); 1400 x 1600 mm (Type 2 hospital) |
| Accessible WC | 2.0 x 2.0 m; with multi-function: 2.2 x 2.2 m |
| Accessible parking | 3.5 m + access; covered preferred |
| Tactile flooring | Per JIS T 9251; at platform edges, ramps, stair tops, level changes |
Japan's robust UD culture extends beyond legal minimum:
| Material | Reference |
|---|---|
| Reinforced Concrete | AIJ-RC / JASS 5 |
| Steel Structures | AIJ-S / JASS 6 |
| Composite (Steel-Reinforced Concrete -- SRC) | AIJ-SRC |
| Wood / Timber | AIJ-W / JASS 11 / JAS lumber + glulam standards |
| Masonry | AIJ-M / JIS A 5406 (block) |
| Foundations | AIJ-F / BSA Articles + JIS A 5525 (piles) |
The Japanese Industrial Standards (JIS) provide product-level specifications:
Japan uses basic wind velocity (Vref) at 30 m height -- varies city by city per AIJ map. Tokyo Vref = 34 m/s. Okinawa coastal (typhoon-prone) Vref up to 46 m/s.
Wind-resistant design also separate consideration:
BCJ evaluates buildings beyond standard limits:
BCJ issues evaluation certificate which the Confirmation Inspection Agency relies on.
| Parameter | Value |
|---|---|
| Cooling design DB (0.4%) | 32-34 deg C |
| Cooling design WB | 26-27 deg C |
| Heating design DB (99.6%) | 0 to -2 deg C |
| Annual CDD (base 18C) | 1100-1300 |
| Annual HDD (base 18C) | 2000-2200 |
| Annual GHI | 1400 kWh/m2 |
| Wind 3-sec gust (typhoon) | 50-55 m/s 0.4% probability |
| Snowfall | < 100 mm typical / yr |
| Parameter | Value |
|---|---|
| Heating design DB | -8 to -10 deg C |
| Annual HDD | 3500+ |
| Snow ground load | 1.5-3.5 kN/m2 (depends on neighbourhood) |
| Parameter | Value |
|---|---|
| Cooling design DB | 32-33 deg C |
| Cooling design WB | 28 deg C |
| Annual CDD | 5000+ |
| Annual HDD | ~50 |
| Typhoon wind | extreme; design 60+ m/s 3-sec gust |
| Salt-laden corrosion | severe |
| Parameter | Value | Source |
|---|---|---|
| Floor-to-floor residential | 2.8-3.0 m | BSA + practice |
| Floor-to-floor office | 3.5-4.0 m | Class A spec; 2.5 m min clear |
| Hotel ceiling clear | 2.4 m min | BSA |
| Corridor width residential (multi-storey) | 1.2 m | BSA Enforcement Order 119 |
| Corridor width Special Building | 1.6 m | BSA Enforcement Order 119 |
| Stair width residential | 1.2 m | BSA Enforcement Order 23 |
| Stair max riser | 23 cm (residential); 18 cm (Special) | BSA |
| Stair min going | 15 cm (residential); 24 cm (Special) | BSA |
| Travel distance sprinklered (general) | 50 m | BSA Enforcement Order 120 |
| Seismic C0 (Level 1) | 0.2 | BSA + AIJ-S |
| Seismic C0 (Level 2) | 1.0 (general); 1.5 (important) | BSA + AIJ-S |
| UA Tokyo (Region 5) | 0.87 W/m2K max | Sho-Energy Ho |
| Yoseki-ritsu Commercial | 200-1300% | City Planning Act |
| Kenpei-ritsu Residential | 30-60% | City Planning Act |
| Daylight hours required (Region 5 winter) | 3 hours mid-winter | Local ordinance |
Cross-references: load building-codes for general code structure (Japan BSA is distinct -- two-statute fire system); fire-life-safety for general principles overlaid by BSA fire-resistance + Fire Service Act active provisions; accessibility-design for global frameworks then Heart Building Law; building-sustainability for CASBEE + LEED + Passivhaus comparison; structural-systems for seismic-specific design (Japan two-level + base isolation expertise); building-envelope for severe climate (subarctic to subtropical) + typhoon detailing.