country-china【设计与创意】People's Republic of China architectural code and regulatory reference. Covers the GB (Guojia Biaozhun -- National Standard) series of mandatory codes including GB 50352-2019 Civil Buildings Unified Design Standard (replaces 2005), GB 50016-2014 (2018 ed.) Fire Protection Design of Buildings, GB 51251-2017 Smoke Control + Prevention, GB 50045 (legacy…
独立 GitHub 快照 · 自动分类 · 以原作者文档为准
Architectural code and regulatory reference for projects in mainland China. Hong Kong SAR has a distinct regulatory regime briefly summarised at Section 12 (different code system, English language, Common Law tradition). Macao SAR also distinct. Taiwan is not covered here.
Activate this skill on any Chinese city reference (Beijing, Shanghai, Guangzhou, Shenzhen, Chengdu, Chongqing, Hangzhou, Nanjing, Tianjin, Wuhan, Xi'an, Suzhou, etc.), CNY/RMB/Yuan currency, mention of "GB 50016"/"GB 50352"/"GB 50011"/"JGJ"/"DB11"/"DGJ08", or Chinese architectural terminology (容积率 yongji-lv, 建筑密度 jianzhu-midu, 日照 rizhao, 抗震 kangzhen, 防火 fanghuo).
China operates as Archetype D (Centralised National + Strong-Form Mandatory Clauses). National GB codes are mandatory throughout the country; local DB supplements may only be more stringent, never less.
LEVEL 1 -- NATIONAL
Ministry of Housing and Urban-Rural Development (MOHURD, Zhufang he Chengxiang Jianshe Bu)
-- primary building authority
+ State Administration for Market Regulation (SAMR) -- approves standards
+ Standardization Administration of China (SAC) -- standards body
Ministry of Emergency Management (MEM, Yingji Guanli Bu) -- fire approvals
(transferred from Public Security Fire Department in 2018)
Ministry of Ecology and Environment (MEE)
National Energy Administration (NEA) -- energy policy
Ministry of Industry and Information Technology (MIIT) -- industrial
China Disabled Persons' Federation (Canlianhui) -- accessibility policy
LEVEL 2 -- PROVINCE (sheng) + AUTONOMOUS REGION + MUNICIPALITY DIRECTLY UNDER CENTRAL GOVT
4 Municipalities: Beijing, Shanghai, Tianjin, Chongqing
23 Provinces (Guangdong, Jiangsu, Zhejiang, Shandong, etc.)
5 Autonomous Regions (Guangxi, Tibet, Inner Mongolia, Ningxia, Xinjiang)
2 SARs (Hong Kong, Macao) -- own systems
Each issues:
DB Local Standards (e.g., DB11 Beijing, DGJ08 Shanghai, DBJ Guangxi 45, DB Guangdong 44, DB Zhejiang 33)
Provincial Construction Department (Sheng Jianshe Ting)
Provincial Fire Department (now Yingji Ting)
LEVEL 3 -- PREFECTURE / CITY
Local Construction Bureau (Jianshe Ju)
Planning Bureau (Guihua Ju, now usually merged with Natural Resources Bureau Ziyuan Ju)
Emergency Management Bureau (Yingji Guanli Ju) -- former Fire Department
Land + Resources Bureau (Guotu Ju, now Natural Resources Bureau)
Environmental Protection Bureau (Huanbao Ju)
LEVEL 4 -- DISTRICT / COUNTY
Smaller cities + counties -- delegated authority from prefecture
LEVEL 5 -- PROJECT
Construction Engineering Planning Permit (Jianshe Gongcheng Guihua Xuke Zheng) from Planning
Construction Permit (Shigong Xuke Zheng) from Construction Bureau
Construction-Engineering Quality Supervision (Zhiliang Jiandu) from Construction Quality Office
Fire approval (Xiaofang Shenpi) from Emergency Management Bureau
Inspection by accredited testing institutes
Codes are classified by mandatory level:
A single project must comply with the strictest applicable provision across these layers.
Distinct Chinese process: before construction can begin, all construction drawings must be reviewed by an accredited Construction Drawing Review Institute (Shigong Tu Shencha Jigou) -- private body certified by provincial government. They check compliance with all applicable GB/DB codes. Review takes typically 15-30 days, longer for complex projects.
The "constitution" of Chinese building design. Replaces 2005 version. Defines:
Distinctive Chinese regulation: every residential dwelling must receive a specified number of hours of unobstructed sunlight on the worst day of winter (大寒 Da Han, around 20 January), measured at the lowest occupied window. Targets:
| Climate Zone | Required Sunlight Hours (mid-winter Da Han) |
|---|---|
| Severe Cold (Zone I) | ≥3 h |
| Cold (Zone II) | ≥3 h |
| Hot Summer Cold Winter (Zone III) | ≥2 h |
| Hot Summer Warm Winter (Zone IV) | ≥1 h or local rule |
| Temperate (Zone V) | ≥2 h |
This drives Chinese urban form: long parallel slab blocks (north-south or oriented), substantial spacing between blocks, distinct from Western tower-on-podium. Calculation per GB 50180-2018 + local rules.
| Building Height | Classification | Implications |
|---|---|---|
| < 24 m (≤ 10 storey roughly) | Low/Multi-storey | Standard rules |
| 24-100 m | High-rise (Gao Ceng) | GB 50016 high-rise rules; sprinklered above 27 m residential or 24 m public |
| > 100 m | Super-High-Rise (Chao Gao Ceng) | Additional rules; structural performance review |
| > 250 m | Super-Tall | Special structural performance review by national experts |
The single most-cited code on Chinese projects. Major 2018 amendment post the SCMP-reported high-rise fires. Replaces older legacy codes including GB 50045-95 (high-rise specific).
Structure:
| Category | Examples |
|---|---|
| Class I High-Rise (Yiji Gao Ceng) | Hospitals, broadcasting + telecom centres (over 50 m), >100 m public, large train station, conference, exhibition |
| Class II High-Rise (Erji Gao Ceng) | Most office, hotel, commercial high-rise; >50 m residential; >24 m public general |
| High-Rise Residential | All residential ≥ 27 m -- with special sub-categories at 54 m, 100 m, 200 m thresholds |
| Multi-Storey | Buildings < 24 m public OR < 27 m residential |
| Class | Description |
|---|---|
| First Class (Yiji) | Non-combustible structural members; 3 h frame; 1.5 h floors |
| Second Class (Erji) | Non-combustible; 2.5 h frame; 1 h floors |
| Third Class (Sanji) | Mixed; 2 h frame |
| Fourth Class (Siji) | Combustible structure tolerated; 0.5 h frame |
High-rise (Class I + II) must be at least First Class. Residential mid-rise often Second Class.
| Parameter | Value |
|---|---|
| Max travel distance (residential >9 storey) | 40 m (sprinklered); 25 m unsprinklered |
| Max travel distance (office sprinklered) | 40 m one-direction; 80 m two-direction |
| Max travel distance (hospital sprinklered) | 30 m |
| Max travel distance (assembly sprinklered) | 30 m |
| Min corridor width residential | 1.2 m (mid-rise); 1.4 m (high-rise) |
| Min corridor width office mid-rise | 1.4 m |
| Min stair width residential | 1.1 m |
| Min stair width public mid-rise | 1.2 m |
| Min stair width public high-rise | 1.4 m |
| Min door clear width | 0.90 m residential, 1.0 m public |
| Max compartment area residential (Class I high-rise) | 1500 m2 per floor sprinklered |
| Max compartment area public Class I (sprinklered) | 2500 m2 (per fire-resistant compartment) |
Dedicated code for smoke control + smoke prevention. Required for:
Specifies mechanical extract rates, makeup air, pressurization, smoke barriers, dampers.
Post-2010s fires (multiple in Shanghai, Urumqi, Shenyang):
For super-high-rise:
Highest-level energy code, replacing fragments of older codes. Applies to all civil buildings nationally. Co-exists with detailed prescriptive codes below.
Detailed prescriptive code for offices, hotels, hospitals, large commercial. Sets envelope U-values + HVAC efficiency + lighting power density by climate zone.
Each defines envelope U-values + window SHGC by climate sub-zone, building shape coefficient, and floor area.
Five primary thermal climate zones:
| Zone | HDD18 / CDD26 | Cities |
|---|---|---|
| I -- Severe Cold | HDD18 > 6000; CDD26 < 90 | Harbin, Hohhot, Urumqi, Shenyang |
| II -- Cold | 3800 < HDD18 ≤ 6000 | Beijing, Tianjin, Xi'an, Lanzhou, Yinchuan, Datong |
| III -- Hot Summer + Cold Winter (HSCW) | 700 ≤ HDD18 ≤ 2000; 40 ≤ CDD26 ≤ 110 | Shanghai, Hangzhou, Nanjing, Wuhan, Chongqing, Chengdu, Hefei, Jinan |
| IV -- Hot Summer + Warm Winter (HSWW) | HDD18 < 700; CDD26 > 100 | Guangzhou, Shenzhen, Nanning, Haikou, Hong Kong, Macao |
| V -- Temperate | HDD18 ≤ 2000; CDD26 ≤ 10 | Kunming, Lhasa (special), Guiyang, Xichang |
(Plus Zone VI -- alpine -- not commonly built in.)
| Element | Severe Cold (I) | Cold (II) | HSCW (III) |
|---|---|---|---|
| Roof | 0.20-0.30 | 0.30-0.40 | 0.50-0.80 |
| Exterior wall | 0.25-0.40 | 0.40-0.55 | 0.80-1.50 |
| Floor (slab) | 0.30 | 0.45 | -- |
| Window (Uw) | 2.0 | 2.5 | 2.5-3.0 |
| Window SHGC (cooling-dominant SHGC limit; heating-dominant fixed by lower) | 0.50 (winter) | 0.45 | 0.40-0.45 |
(Targets indicative; actual depend on shape factor + floor count + orientation per current code.)
China's national green rating per GB/T 50378-2019 "Assessment Standard for Green Building":
Assessment categories: safety + durability, health + comfort, life + convenience, resource saving, environment livability, innovation.
Mandatory minimum One Star for government investment buildings in many provinces; rising standards.
GB/T 51350-2019 -- Technical Standard for Nearly Zero Energy Buildings -- China's PassivHaus-equivalent track. Three tiers:
Promoted by CABEE (Centre for Building Energy Efficiency) + provincial incentive schemes.
China's accessibility code. Aligned to ISO 21542 + UN CRPD which China ratified.
| Element | Dimension |
|---|---|
| Accessible route | 1.2 m clear (1.5 m preferred); passing space 1.5 x 1.5 m every 25 m |
| Door clear width | 800 mm (900 mm preferred at main entry) |
| Ramp gradient | 1:12 max (1:16 preferred); landings every 9 m |
| Lift cabin | 1100 x 1400 mm (Type 1); 1100 x 2100 mm hospital |
| Accessible WC | 2.0 x 2.0 m (peninsula layout); grab rails left + right |
| Accessible parking | 3.5 m + 1.5 m aisle (or 3.0 + 1.2 m for limited urban contexts) |
| Tactile flooring | Per GB/T 12992-2008 tactile pavement; at level changes, ramps, stair edges, lift entries |
| Hearing loop | All assembly venues > 200 occupants |
Some provinces (Beijing, Shanghai, Guangdong) issue stricter local DB codes for accessibility. Shanghai's DGJ08 series + Beijing's DB11 series include accessibility supplements.
Defines Seismic Intensity (Lieji) -- 6-9 degree scale per Chinese intensity classification (not exactly MMI/MMS):
| Intensity Degree (Lieji) | Description | Approximate PGA |
|---|---|---|
| Degree 6 | Felt by most; minor non-structural damage | 0.05 g (50-year 10% probability) |
| Degree 7 | Light damage to engineered structures | 0.10-0.15 g |
| Degree 8 | Moderate-heavy damage | 0.20-0.30 g |
| Degree 9 | Severe damage; collapse possible | 0.40 g+ |
Cities mapped to intensity:
| Material | Code |
|---|---|
| Concrete | GB 50010-2010 (Code for Design of Concrete Structures) |
| Steel | GB 50017-2017 (Code for Design of Steel Structures) |
| Composite | GB 50017 + GB 50068 |
| Reliability | GB 50068-2018 (Unified Standard for Reliability) |
| Wood | GB 50005-2017 |
| Masonry | GB 50003-2011 |
| Foundations | GB 50007-2011 (Code for Foundation Design); GB 50330-2013 slope; GB 50202-2018 excavation |
| Wind tunnel testing | GB 50009 + Tongji + CABR guidelines |
China divided into basic wind pressure W0 (kN/m2) by region:
3-second-gust speeds derived; typical 30-45 m/s 50-year return.
Hospitals, schools, and other special projects require Class A institutes.
China practice distinguishes:
Many large projects skip "Initial Design" and proceed directly with "Schematic + Construction Drawing" -- but Construction Drawing Review remains mandatory.
| Parameter | Value | Source |
|---|---|---|
| Floor-to-floor residential | 2.8-3.0 m | GB 50352-2019 |
| Floor-to-floor office | 3.6-4.5 m | GB 50352-2019; min 2.5 m clear |
| Hospital floor-to-floor | 4.0-4.5 m | GB 50352-2019 |
| Net ceiling height (residential) | 2.4 m min | GB 50352-2019 |
| Stair width residential | 1.1 m | GB 50352-2019 |
| Stair width public mid-rise | 1.2 m | GB 50352-2019 |
| Travel distance high-rise residential sprinklered | 40 m | GB 50016 Ch. 5 |
| Travel distance office sprinklered (1-way) | 40 m | GB 50016 Ch. 5 |
| Compartment area Class I high-rise sprinklered | 2500 m2 | GB 50016 Ch. 5 |
| Cladding (high-rise residential ≥ 50 m) | Class A non-combustible | GB 50016 + GB 8624 |
| Wall U-value Cold Zone residential | 0.40-0.55 W/m2K | JGJ 26-2018 |
| Window Uw Cold Zone | 2.5 W/m2K | JGJ 26-2018 |
| Sunlight Da Han hours (Beijing) | 3 h | DB11 / National rule |
| Yongji-lv residential (Beijing) | 1.5-3.5 | Local Detailed Reg Plan |
| Basic wind pressure W0 Beijing | 0.45 kN/m2 | GB 50009 |
| Seismic intensity Beijing | Degree 8 | GB 50011-2010 |
Hong Kong has its own Building Regulations under Buildings Ordinance (Cap. 123). Distinct system:
Hong Kong common law tradition, English-language, but uses OB (Outline Zoning Plan) for planning. Not covered in detail here -- consult HK-specific resources.
Macao has its own building law (Lei 32/96/M) + technical regulations. Portuguese-tradition + Chinese hybrid. Not detailed here.
Cross-references: load building-codes for general code structure (China is unique with mandatory red-text clauses); fire-life-safety for general principles overlaid by GB 50016 + GB 51251; accessibility-design for global frameworks then GB 50763; building-sustainability for Green Building Label + LEED comparison + GB/T 51350 NZEB; structural-systems for seismic design (Chinese intensity scale + GB 50011); building-envelope for 5-climate-zone tropical + cold + alpine detailing.