iso10993-evaluator

iso10993-evaluator

Biological evaluation planning skill implementing ISO 10993-1 for biocompatibility testing strategy

Independent GitHub snapshot · Automated classification · Original documentation governs

Skill documentation

GitHub

name: iso10993-evaluator description: Biological evaluation planning skill implementing ISO 10993-1 for biocompatibility testing strategy allowed-tools:

  • Read
  • Write
  • Glob
  • Grep
  • Edit
  • Bash metadata: specialization: biomedical-engineering domain: science category: Biocompatibility and Materials skill-id: BME-SK-016 graph: domains: [domain:biomedical-engineering] skillAreas: [skill-area:statistical-analysis, skill-area:data-analysis, skill-area:compliance-automation] workflows: [workflow:experiment-design, workflow:peer-review-cycle] roles: [role:biomedical-engineer, role:lab-technician]

ISO 10993 Evaluator Skill

Purpose

The ISO 10993 Evaluator Skill supports biological evaluation planning per ISO 10993-1, determining biocompatibility testing requirements based on device categorization, contact type, and duration.

Capabilities

  • Device categorization (body contact, duration)
  • Testing endpoint determination matrix
  • Existing data evaluation guidance
  • Equivalence assessment templates
  • Gap analysis for testing requirements
  • Biological evaluation plan generation
  • Report template generation
  • Risk-based testing strategy
  • Alternative testing approaches
  • Literature review guidance
  • Toxicological risk assessment support

Usage Guidelines

When to Use

  • Planning biocompatibility testing programs
  • Evaluating existing biocompatibility data
  • Assessing material equivalence
  • Preparing biological evaluation reports

Prerequisites

  • Device materials identified
  • Contact type and duration defined
  • Manufacturing process documented
  • Existing data compiled

Best Practices

  • Apply risk-based approach per ISO 10993-1:2018
  • Evaluate existing data before new testing
  • Consider material equivalence carefully
  • Document rationale for testing decisions

Process Integration

This skill integrates with the following processes:

  • Biological Evaluation Planning (ISO 10993)
  • Extractables and Leachables Analysis
  • Biomaterial Selection and Characterization
  • 510(k) Premarket Submission Preparation

Dependencies

  • ISO 10993 series standards
  • FDA G95-1 guidance
  • Material databases
  • Testing laboratory capabilities
  • Toxicological databases

Configuration

iso10993-evaluator:
  contact-categories:
    - surface-device
    - external-communicating
    - implant
  contact-types:
    - skin
    - mucosal-membrane
    - breached-surface
    - blood-path-indirect
    - tissue-bone
    - blood
  duration-categories:
    - limited
    - prolonged
    - permanent

Output Artifacts

  • Device categorization documents
  • Testing requirement matrices
  • Biological evaluation plans
  • Gap analysis reports
  • Equivalence assessments
  • BER templates
  • Literature review summaries
  • Testing rationale documents

Quality Criteria

  • Categorization follows ISO 10993-1:2018
  • Testing endpoints appropriate for device
  • Existing data properly evaluated
  • Equivalence arguments supported
  • Gap analysis comprehensive
  • Documentation supports regulatory review