L’interface est localisée ; les présentations et documents des Skills sont traduits automatiquement par IA dans votre langue. Le code, les commandes, chemins et termes techniques restent en version originale, et le document de l’auteur fait foi.
Explorer les Skills
Design et création · SKILL.md

chest-xray-analysis

chest-xray-analysis

Operate MedRAX chest-X-ray classification, segmentation, report, visual-QA, phrase-grounding, and optional image-generation tools with explicit resource and output checks.

Independent GitHub snapshot · Automated classification · Original documentation governs

Documentation de la Skill

GitHub

name: chest-xray-analysis description: "Operate MedRAX chest-X-ray classification, segmentation, report, visual-QA, phrase-grounding, and optional image-generation tools with explicit resource and output checks." disable-model-invocation: true metadata: disco-role: operating license: Apache 2.0

Chest X-ray analysis

Use this skill when a Researcher needs to operate one of MedRAX's chest-X-ray model tools on an already available JPG or PNG image. Treat all model outputs as assistive observations, not a diagnosis or a measurement suitable for clinical decision-making without qualified review.

Scope and routing

  • Use classification for a bounded screen across the 18 TorchXRayVision pathology labels.
  • Use segmentation for anatomical masks, an overlay, and approximate image metrics; route DICOM conversion or display concerns to image-data-utilities.
  • Use report generation for a deterministic two-section findings/impression draft.
  • Use CheXagent VQA for multi-image visual questions and broad CXR reasoning.
  • Use MAIRA-2 grounding for a phrase and its localized bounding boxes.
  • Use LLaVA-Med only for optional, broad medical visual QA; it is not the preferred detailed CXR interpreter.
  • Use RoentGen generation only for synthetic-image experiments when its manually supplied weights are already available.
  • Route tool selection, graph execution, and agent state to agent-orchestration; route benchmark claims to benchmark-evaluation.

Do not accept DICOM as a direct input to these tools: the tool schemas describe JPG/PNG paths. Use the image-data utility workflow before analysis when a DICOM study must be converted, and preserve the fact that conversion can change metadata and pixel semantics.

Fast decision matrix

NeedSelectMain cost or caveat
18-label abnormality likelihoodsChestXRayClassifierToolDenseNet weights; values are probabilities, not calibrated diagnoses
Organ boundaries/overlayChestXRaySegmentationToolPSPNet; area is not accurate for non-DICOM input
Findings plus impression proseChestXRayReportGeneratorToolTwo encoder-decoder models; substantial model storage
Ask one or more image questionsXRayVQAToolCheXagent 2-3B, remote code, usually CUDA and bfloat16
Locate a phraseXRayPhraseGroundingToolMAIRA-2; CUDA and optional bitsandbytes are practical constraints
General medical image QALlavaMedToolLarge optional model; implementation uses CUDA tensors directly
Create a synthetic CXRChestXRayGeneratorToolRoentGen weights must be supplied manually; no clinical use

For a low-memory run, start with CPU-side path/schema validation, then choose one CUDA tool: classifier for labels, segmentation for anatomy, grounding with 8-bit loading for localization, or CheXagent only when QA is essential. Keep report generation, LLaVA-Med, and RoentGen disabled until their weights, CUDA memory, and compatible dependencies are proven. This selection verifies resource discipline, not model quality; unrun models remain unverified.

Operating procedure

  1. Preflight without loading models. Run the bundled validator from scripts/validate_inputs.py. Confirm regular files, .jpg, .jpeg, or .png suffixes, required text fields, positive token/image parameters, and exact segmentation organ names.
  2. Declare resources. Record the requested device, dtype, quantization, caller-managed cache/temp locations, whether weights are already present, and whether the run may use external model access. Never silently download a large model or require credentials.
  3. Construct only the selected tool. Constructor options and model prerequisites are in references/api-reference.md and references/model-overview.md. Avoid initializing every tool at once.
  4. Invoke with the tool schema. MedRAX tools are LangChain BaseTool objects; pass the documented field names. They return a value plus metadata (except an error may be encoded in the value). Check analysis_status and preserve returned paths before interpreting content.
  5. Check output semantics. Classifier scores are per-label likelihood values. Segmentation metrics are mask-derived image metrics. Grounding boxes use normalized coordinates unless converted to original-image pixels. Generated prose and images require human review.
  6. Recover narrowly. For an error, use the matching row in references/troubleshooting.md; do not switch devices, quantization, or model sources blindly. Re-run only after recording the changed setting.

Output checklist

  • Record input image identity, requested tool, constructor settings, device, dtype/quantization, model availability, and analysis_status.
  • Classification returns (scores, metadata) where scores map the 18 labels to numeric values in the source's 0–1 convention.
  • Segmentation returns (output, metadata): segmentation_image_path, a per-organ metrics dictionary, original/model sizes, requested and processed organs, and the fixed pixel-spacing assumption. An empty organ result is not proof of absence.
  • Reports contain CHEST X-RAY REPORT, FINDINGS, and IMPRESSION, plus metadata listing both generated sections.
  • VQA returns {"response": text} and metadata containing image paths, prompt, token limit, and status. It does not expose a calibrated confidence score.
  • Grounding returns predictions with model and original-image boxes and may return visualization_path; completed_no_finding is distinct from failure.
  • LLaVA-Med returns answer text and question/image/status metadata.
  • RoentGen returns a generated image_path and prompt, sampling, device, and size metadata. Generated images are synthetic artifacts, not evidence.

High-risk interpretation rules

  • Do not threshold classifier scores as diagnoses unless a separately validated threshold is supplied; the tool supplies no threshold or calibration.
  • Do not report segmentation area_cm2 as physically accurate for JPG/PNG. The implementation uses a fixed 0.2 mm/pixel assumption; request DICOM-aware processing for measurement work and route conversion/display separately.
  • Grounding coordinates are [x_min, y_min, x_max, y_max] in normalized model/image conventions as documented in the API reference. Use the returned image_coordinates for the original image and do not mix the two spaces.
  • A missing/empty prediction, a failed model load, and a model's negative finding are different observations. Preserve status and error metadata.
  • Reports, VQA answers, LLaVA answers, and generated images can hallucinate; corroborate with the image and an appropriate validated workflow.

References

  • API reference: exact fields, constructors, outputs, labels, coordinates, and artifacts.
  • Model overview: weights, devices, dtypes, quantization, caches, and external-resource boundaries.
  • Workflows: bounded selection and low-memory runs.
  • Troubleshooting: predictable failures and recovery actions.
  • Safe input validator: local path/schema checks only; it never imports model libraries, downloads weights, or runs inference.
Skills enregistrées