L’interface est localisée ; les présentations et documents des Skills sont traduits automatiquement par IA dans votre langue. Le code, les commandes, chemins et termes techniques restent en version originale, et le document de l’auteur fait foi.
Explorer les Skills
Données et recherche · SKILL.md

plan-spectroscopic-analysis

plan-spectroscopic-analysis

Plan spectroscopic analysis campaign: define analytical question, assess sample, pick techniques via decision matrix, plan prep per technique, sequence non-destructive → destructive, define success criteria w/ cross-validation strategy.

Independent GitHub snapshot · Automated classification · Original documentation governs

Documentation de la Skill

GitHub

name: plan-spectroscopic-analysis locale: caveman-ultra source_locale: en source_commit: 82c77053 fence_basis_commit: 82c77053 translator: "Julius Brussee homage — caveman" translation_date: "2026-04-26" description: > Plan spectroscopic analysis campaign: define analytical question, assess sample, pick techniques via decision matrix, plan prep per technique, sequence non-destructive → destructive, define success criteria w/ cross-validation strategy. license: MIT allowed-tools: Read Grep Glob WebFetch WebSearch metadata: author: Philipp Thoss version: "1.0" domain: spectroscopy complexity: intermediate language: natural tags: spectroscopy, analytical-planning, technique-selection, sample-preparation

Plan Spectroscopic Analysis

Design spectroscopic campaign: pick right techniques, sequence efficiently, define success criteria → answer specific analytical question.

Use When

  • Investigate unknown compound → which spectroscopic techniques?
  • Optimize analysis sequence → preserve sample for destructive methods
  • Plan sample prep before instrument time
  • Cross-validate complementary techniques
  • Budget instrument time + prioritize when resources limited
  • Train new analysts in systematic planning

In

  • Required: Analytical question (structure ID, quantitation, purity, functional group screen, reaction monitoring)
  • Required: Sample desc (physical state, qty, known/suspected class)
  • Optional: Available instruments + capabilities
  • Optional: Budget + time constraints
  • Optional: Safety data (toxicity, reactivity, volatility, light)
  • Optional: Prior data (if any)

Do

Step 1: Define Analytical Question

Clarify info needed before picking technique.

  1. Classify question:

    • Structure ID: Full molecular structure of unknown. Broadest set.
    • Structure confirm: Known compound matches expected. Few, focused on diagnostics.
    • Quantitative: Concentration of known analyte. Calibration + good linearity (UV-Vis, NMR w/ internal std).
    • Purity: Impurities present? Identify? High sensitivity + separation.
    • Functional group screen: Which groups present, no full structure. IR often enough.
    • Reaction monitor: Track reaction over time. Speed + compatibility w/ conditions (in situ IR, Raman, UV-Vis).
  2. Success criteria: Explicit. Structure ID → "single proposal consistent w/ all data". Quantitation → "concentration w/ <5% rel error".

  3. Existing knowledge: Compile (elemental analysis, reaction scheme, expected product, lit precedent). Constrains problem, fewer techniques needed.

→ Clear analytical question w/ success criteria + existing knowledge summary.

If err: question vague ("characterize this") → narrow w/ requestor. Vague → unfocused → wasted instrument time.

Step 2: Assess Sample Characteristics

Eval sample → which techniques feasible.

  1. Physical state: Solid (crystalline, amorphous, powder), liquid, solution, gas, thin film, biological tissue. Each constrains prep + technique.
  2. Quantity: Total mass/vol. NMR needs mg, MS µg, SERS ng.
  3. Solubility: Test/estimate in common solvents (water, methanol, DMSO, chloroform, hexane). NMR → deuterated solvent. UV-Vis → transparent.
  4. Stability: Thermal (GC-MS needs volatilization), photo (Raman uses laser), air/moisture (KBr pellet), solution (time-dependent).
  5. Safety: Toxicity, flammability, reactivity, radioactivity. Affects handling, may exclude techniques (volatile toxics → no open-atmosphere Raman w/o containment).
  6. MW range: Small (<1000 Da) vs polymers/biomolecules (>1000 Da) → different MS ionization + NMR strategies.

→ Sample characterization summary: state, qty, solubility, stability, hazards, MW range.

If err: can't characterize adequately (qty too small to test solubility) → conservative: start non-destructive minimal-sample (Raman, ATR-IR), reassess after.

Step 3: Select Techniques via Decision Matrix

Pick most informative techniques based on question + sample.

TechniqueBest ForSample NeedsDestructive?SensitivityKey Limitations
1H NMRH connectivity, integration, coupling1--10 mg in deuterated solventNomgRequires solubility, insensitive
13C NMRCarbon skeleton, functional groups10--50 mg in deuterated solventNomgVery insensitive, long acquisition
2D NMRFull connectivity, stereochemistry5--20 mg in deuterated solventNomgHours of instrument time
IR (ATR)Functional group IDAny solid/liquid, minimal prepNougWater interference, fingerprint overlap
IR (KBr)Functional group ID, transmission1--2 mg solid in KBr pelletNo*ugMoisture sensitive, sample mixed
RamanSymmetric modes, aqueous samplesAny state, no prep for solidsNoug--mgFluorescence, photodegradation
EI-MSVolatile small molecules, fragmentationug, must be volatileYes (GC-MS)ng--ugRequires volatility
ESI-MSPolar/large molecules, MW determinationSolution in volatile solventYespg--ngAdduct complexity, ion suppression
MALDI-MSPolymers, proteins, large moleculesSolid + matrixYesfmolMatrix interference below 500 Da
UV-VisChromophores, quantitationSolution, ug--mgNougLimited structural information

*IR with KBr is non-destructive to the molecule but the sample cannot be easily recovered from the pellet.

  1. Match question to technique: Structure ID → NMR + MS + IR min. Functional group → IR only. Quantitation → UV-Vis or NMR best.
  2. Feasibility: Cross-ref candidates w/ Step 2 sample. Eliminate incompatible (GC-MS for non-volatile, NMR for paramagnetic).
  3. Prioritize by info density: Rank by info per question.
  4. Cost + availability: If equal info, prefer faster, cheaper, more available.

→ Ranked list of techniques w/ justification + excluded ones w/ reasons.

If err: no single sufficient (common for structure ID) → plan complementary techniques together. None suitable → note limitation, recommend alts (derivatization → GC-MS).

Step 4: Plan Sample Prep per Technique

Prep reqs per selected technique.

  1. NMR prep: Dissolve 1-50 mg in 0.5-0.7 mL deuterated solvent. Solvent by solubility + spectral window:
Solvent1H ResidualUse When
CDCl37.26 ppmNon-polar to moderately polar compounds
DMSO-d62.50 ppmPolar compounds, broad solubility
D2O4.79 ppmWater-soluble compounds, peptides
CD3OD3.31 ppmPolar organic compounds
C6D67.16 ppmAromatic region overlap avoidance
  1. IR prep: Method by sample state:

    • ATR: Solid/liquid direct on crystal. Fastest, minimal prep.
    • KBr pellet: Grind 1-2 mg w/ 100-200 mg dry KBr, press into transparent disk.
    • Solution cell: Dissolve in IR-transparent solvent (CCl4, CS2). Limited transparency windows.
    • Thin film: Cast from solution onto NaCl/KBr window. Polymers + oils.
  2. MS prep: Match ionization to sample:

    • EI (GC-MS): Sample volatile. Volatile solvent (DCM, hexane).
    • ESI (LC-MS): ESI-compatible solvent (methanol/water, acetonitrile/water w/ 0.1% formic acid).
    • MALDI: Mix w/ matrix (DHB, CHCA, sinapinic acid), dry on target.
  3. UV-Vis prep: UV-transparent solvent. Conc → absorbance at lambda-max 0.1-1.0. Matched cuvettes for sample + ref.

  4. Raman prep: Minimal. Solids neat. Liquids in glass vials (weak Raman). Avoid fluorescent containers. Aqueous solutions OK (water = weak Raman scatterer).

→ Prep protocol per technique: solvents, qtys, special handling.

If err: qty insufficient for all → prioritize by Step 3 hierarchy. Insoluble in all suitable → solid-state techniques (ATR-IR, Raman, solid-state NMR, MALDI-MS).

Step 5: Sequence + Cross-Validation Strategy

Order analyses → preserve sample, max info flow.

  1. Sequence by destructiveness: Non-destructive first, destructive last.

    • Tier 1 (non-destructive, no prep): Raman, ATR-IR
    • Tier 2 (non-destructive, requires prep): UV-Vis, NMR (sample often recoverable by evaporation)
    • Tier 3 (destructive or consumes sample): MS (ESI, EI/GC-MS, MALDI)
  2. Info flow: Early results refine later:

    • IR/Raman functional groups → choose NMR experiments (no carbonyl in IR → skip carbonyl-focused 13C).
    • MW from MS → interpret NMR (integration ratios, peak count).
    • NMR connectivity → interpret MS fragmentation.
  3. Cross-validation points: Where techniques must agree:

    • Molecular formula: MS (mol ion) = NMR (H + C count) = elemental analysis.
    • Functional groups: IR assignments consistent w/ NMR shifts + MS fragmentation.
    • Degree of unsaturation: From formula (MS) = observed rings + double bonds (NMR, UV-Vis).
  4. Contingencies: What if ambiguous:

    • NMR unexpected complexity → run 2D (COSY, HSQC, HMBC).
    • MS mol ion ambiguous → different ionization or HRMS.
    • IR dominated by one group → Raman for complementary.
  5. Document plan: Written plan w/ sequence, prep, turnaround, decision points.

→ Complete ordered plan w/ prep, cross-validation, contingencies doc'd.

If err: plan can't complete due to sample/instrument → doc limitations, propose best achievable subset.

Check

  • Analytical question clear w/ explicit success criteria
  • Sample characteristics assessed (state, qty, solubility, stability, hazards)
  • Techniques selected via decision matrix w/ justifications
  • Infeasible techniques excluded w/ reasons
  • Sample prep planned per technique
  • Analysis sequence non-destructive → destructive
  • Cross-validation points defined
  • Contingency experiments ID'd for ambiguous
  • Total sample consumption estimated vs available qty

Traps

  • Skip planning: Jumping to nearest instrument → wastes sample + time. 15 min planning saves hours of re-analysis.
  • Pick by habit not need: Not every analysis needs NMR. Functional group confirm → only IR. Match technique to question.
  • Underestimate sample reqs: Running out mid-sequence avoidable. Calc total upfront + 20% reserve.
  • Destructive methods first: GC-MS before NMR → NMR needs separate aliquot. Non-destructive first → max info per mg.
  • Neglect solvent compat: Sample in DMSO-d6 (NMR) → not easy for GC-MS (non-volatile). Plan solvents across all.
  • No cross-validation strategy: No checkpoints → contradictory results unnoticed until final interp.

→

  • interpret-nmr-spectrum — interpret NMR per this plan
  • interpret-ir-spectrum — interpret IR per this plan
  • interpret-mass-spectrum — interpret MS per this plan
  • interpret-uv-vis-spectrum — interpret UV-Vis per this plan
  • interpret-raman-spectrum — interpret Raman per this plan
  • validate-analytical-method — validate quantitative methods from this plan
Skills enregistrées