L’interface est localisée ; les présentations et documents des Skills sont traduits automatiquement par IA dans votre langue. Le code, les commandes, chemins et termes techniques restent en version originale, et le document de l’auteur fait foi.
Explorer les Skills
Productivité · SKILL.md

hardware-provisioning

hardware-provisioning

Plans and provisions Linux systems for cloud instances and on-prem hardware with workload-appropriate sizing, RAID, and hardware abstraction.

Independent GitHub snapshot · Automated classification · Original documentation governs

Documentation de la Skill

GitHub

name: hardware-provisioning description: Plans and provisions Linux systems for cloud instances and on-prem hardware with workload-appropriate sizing, RAID, and hardware abstraction. license: MIT compatibility: opencode metadata: version: "1.0.0" domain: linux role: implementation scope: implementation output-format: code content-types:

  • code
  • guidance
  • config
  • do-dont triggers: hardware provisioning, instance sizing, RAID configuration, SSD, cloud instance, on-prem hardware, disk sizing, CPU architecture archetypes:
  • tactical anti_triggers:
  • brainstorming
  • vague ideation response_profile: verbosity: low directive_strength: high abstraction_level: operational related-skills: resource-management, kernel-tuning, storage-architecture, linux-security maturity: stable completeness: 95 exampleCount: 3

Linux Hardware Provisioning

Infrastructure engineer planning and provisioning Linux systems for cloud instances and on-prem hardware, selecting appropriate sizing, configuring RAID/storage, and abstracting hardware differences for consistent operation.

TL;DR Checklist

  • Define workload requirements (CPU, memory, storage I/O, network bandwidth) before selecting hardware
  • Choose cloud instance type or on-prem hardware that matches workload profile
  • Verify CPU architecture compatibility (x86_64 vs ARM64) for all software dependencies
  • Select RAID level based on workload durability vs performance requirements
  • Configure SSD/NVMe optimization (TRIM support, I/O scheduler)
  • Set up hardware monitoring (SMART, IPMI, sensor data)
  • Document hardware inventory and configuration for change management
  • Test workload on target hardware with representative benchmarks before production deployment

When to Use

Use this skill when:

  • Selecting cloud instances — You're choosing instance types and sizes for workloads across AWS, GCP, Azure, or other providers
  • Building on-prem servers — You're procuring and configuring physical servers for deployment
  • Storage architecture planning — You need to select RAID levels, disk types (SSD/NVMe/HDD), and capacity for the workload
  • Cross-architecture deployment — You're deploying software that must run on both x86_64 and ARM64 platforms
  • Hardware capacity planning — You're sizing infrastructure to handle projected growth and peak load

When NOT to Use

Avoid this skill for:

  • Software application development — Hardware provisioning is an infrastructure concern, not an application concern
  • Network configuration — Use networking skill for interface, bonding, and firewall configuration
  • OS-level tuning — Use kernel-tuning for performance optimization after hardware is selected
  • When hardware is fully managed by cloud provider — Bare metal services and managed databases abstract hardware selection away

Use storage-architecture for filesystem, LVM, and mount option configuration after storage hardware is provisioned. Use resource-management for post-provisioning resource allocation and workload isolation.


Core Workflow

1. Define Workload Requirements

Quantify hardware needs based on workload characteristics.

Workload Type          CPU     Memory     Storage I/O     Network
─────────────────────────────────────────────────────────────────
Web/API Server         4-16   8-32 GB    Moderate        1-10 Gbps
Database (OLTP)        8-64   32-256 GB  High (low lat)  1-25 Gbps
Database (OLAP)        16-128 64-512 GB  Very High       10-100 Gbps
Batch/Compute          32-256 64-1024 GB Low-Moderate    1-10 Gbps
Storage Server         8-32   32-128 GB  Very High       10-100 Gbps
Monitoring             2-8    4-16 GB    Moderate        1 Gbps

Checkpoint: Workload requirements are documented with minimum and recommended specs, backed by benchmark data or industry references.

2. Select Cloud Instance Type

Match workload to cloud instance family.

AWS — Query available instance types by family

# List general purpose instances with specs
aws ec2 describe-instance-types \
  --filters "Name=instance-type-group-name,Values=general*\" \
  --query 'InstanceTypes[*].[InstanceType,VCPUs,MemoryInfo.SizeInMiB,ProcessorInfo.SupportedArchitectures[0]]' \
  --output table

# List memory-optimized instances
aws ec2 describe-instance-types \
  --filters "Name=instance-type-group-name,Values=memory*" \
  --query 'InstanceTypes[*].[InstanceType,VCPUs,MemoryInfo.SizeInMiB,EbsOptimizedInfo.MaximumEbsBandwidthInGbps]' \
  --output table

# Get pricing for a specific instance (requires Price List API)
aws pricing get-products \
  --service-code AmazonEC2 \
  --filters 'Field=instanceType,Value=m7i.xlarge,MatchOptions=EXACT' \
  --region us-east-1 \
  --output json | jq '.PriceList[0] | fromjson | .product.attributes | {instance_type: instanceType, vcpus: vcpu, memory_gb: memory, storage: storage, price_usd: pricePerUnit.usd}'

GCP — Query available instance types

# List machine types with specs
gcloud compute machine-types list \
  --filter="name~'n2-standard' OR name~'m2-ultra' OR name~'c2d'" \
  --format='table[name,zones[0],guest_cpus,memory_mb,local_ssd_disk]'

# List AMD compute-optimized instances
gcloud compute machine-types list \
  --filter="name~'c2d-84' AND zones~'us-east1'" \
  --format='table[name,guest_cpus,memory_mb,local_ssd_disk,networking.guest_cpus_per_nic]'

Instance selection by workload type

#!/bin/bash
# Select instance type based on workload requirements
# Usage: ./select-instance.sh workload-type provider [region]

WORKLOAD="${1:-database}"
PROVIDER="${2:-aws}"
REGION="${3:-us-east-1}"

case "$WORKLOAD" in
    database)
        case "$PROVIDER" in
            aws)
                echo "AWS: r7i.xlarge (4 vCPU, 32 GB RAM, 12K IOPS, 125$/mo)"
                echo "       r7i.2xlarge (8 vCPU, 64 GB RAM, 12K IOPS, 250$/mo)"
                ;;
            gcp)
                echo "GCP: n2-standard-4 (4 vCPU, 16 GB RAM, 12K IOPS, 110$/mo)"
                echo "     m2-ultramem-208 (208 vCPU, 2912 GB RAM, 1.6M IOPS, 5500$/mo)"
                ;;
        esac
        ;;
    web)
        case "$PROVIDER" in
            aws) echo "AWS: m7i.xlarge (4 vCPU, 16 GB, gp3, 5Gbps, 91$/mo)" ;;
            gcp) echo "GCP: n2-standard-4 (4 vCPU, 16 GB, pd-ssd, 16Gbps, 110$/mo)" ;;
        esac
        ;;
    compute)
        case "$PROVIDER" in
            aws) echo "AWS: c7i.xlarge (4 vCPU, 8 GB, gp3, 5Gbps, 75$/mo)" ;;
            gcp) echo "GCP: c2d-84 (84 vCPU, 336 GB, local-ssd, 4Tbps, 2100$/mo)" ;;
        esac
        ;;
    *)
        echo "Unknown workload: $WORKLOAD"
        echo "Supported: database, web, compute, batch, storage"
        exit 1
        ;;
esac

Checkpoint: Instance type is selected that meets minimum requirements with room for growth. Cost is documented.

3. Configure RAID for On-Prem Hardware

Select and configure RAID based on workload needs.

RAID Level   Durability   Performance    Capacity Efficiency    Best For
────────────────────────────────────────────────────────────────────────────────
RAID 0       None         Max read/write 100%            Development, cache
RAID 1       1 disk loss  Good read,   50%                    OS disk, boot
                         moderate write
RAID 5       N-1 disks    Good read,     (N-1)/N               Read-heavy workloads
                         degraded write
RAID 6       N-2 disks    Good read,     (N-2)/N               Critical storage, NAS
                         degraded write
RAID 10      1 per mirror Max read/write  50%                    High-performance DB
RAID 50      N-1 per set  Good           (N-k)/N               Large read-heavy arrays
RAID 60      N-2 per set  Good           (N-k)/N               Large critical arrays
# Configure RAID 10 with mdadm for database
sudo mdadm --create /dev/md0 --level=10 --raid-devices=4 \
    /dev/sdb /dev/sdc /dev/sdd /dev/sde \
    --chunk=256 --metadata=1.2 --name=db-data

# Configure RAID 6 with mdadm for storage
sudo mdadm --create /dev/md1 --level=6 --raid-devices=6 \
    /dev/sdf /dev/sdg /dev/sdh /dev/sdi /dev/sdj /dev/sdk \
    --chunk=64 --metadata=1.2 --name=storage-data

# Create filesystem on RAID array
sudo mkfs.xfs -f /dev/md0
sudo mkfs.xfs -f /dev/md1

# Add mdadm configuration for persistence
sudo mdadm --detail --scan | sudo tee -a /etc/mdadm/mdadm.conf
sudo update-initramfs -u  # Debian/Ubuntu
sudo dracut --force       # RHEL/CentOS

Checkpoint: RAID array is assembled, filesystem is created, and mdadm configuration persists across reboots.

4. Optimize SSD/NVMe Performance

Configure SSD-specific settings for maximum performance and longevity.

# Verify TRIM/discard support
sudo fstrim -v /mount/point

# Set I/O scheduler for SSD/NVMe (none/mq-deadline for NVMe)
echo "none" | sudo tee /sys/block/sdX/queue/scheduler
# For NVMe:
echo "none" | sudo tee /sys/block/nvme0n1/queue/scheduler

# Set read-ahead for workload type (default 128 sectors = 64KB)
# Sequential workloads benefit from higher read-ahead
sudo blockdev --setra 4096 /dev/sdX   # 4096 sectors = 2MB read-ahead

# Enable write-back caching (faster but loses data on power failure)
# Use only with UPS or write-through for critical data
sudo hdparm -W1 /dev/sdX

# NVMe-specific: optimize queue depth
echo 1024 | sudo tee /sys/block/nvme0n1/queue/nr_requests

# Create persistent udev rule for SSD optimizations
cat > /etc/udev/rules.d/60-ssd.rules << 'UDEV'
# Set I/O scheduler for all SSDs
ACTION=="add|change", ATTR{queue/rotational}=="0", ATTR{queue/scheduler}="mq-deadline"
# Set read-ahead for SSDs
ACTION=="add|change", ATTR{queue/rotational}=="0", ATTR{queue/read_ahead_kb}="2048"
# Enable TRIM for SSDs
ACTION=="add|change", ATTR{queue/rotational}=="0", ATTR{queue/discard_max_bytes}!="0", ATTR{queue/discard_granularity}!="0"
UDEV

Checkpoint: I/O scheduler is set to mq-deadline/none for SSDs, TRIM is operational, and read-ahead is tuned for the workload.

5. Verify CPU Architecture Compatibility

Ensure software runs correctly on the target CPU architecture.

# Detect CPU architecture
uname -m                        # x86_64, aarch64, arm64
lscpu | grep -E "Architecture|Model name|CPU\(s\)"

# Check CPU features
grep -oP '^flags\s+:\K.*' /proc/cpuinfo | tr ' ' '\n' | sort -u

# Verify emulation support (running ARM on x86 via QEMU)
dpkg --print-architecture       # Current architecture
dpkg --print-foreign-architectures  # Emulated architectures

# For cross-architecture deployment:
# x86_64 → deploy native packages
# aarch64 → deploy ARM64 packages or build from source

Checkpoint: Target architecture is identified and all software dependencies have compatible builds for the architecture.

6. Set Up Hardware Monitoring

Configure monitoring for hardware health and early failure detection.

# Install hardware monitoring tools
sudo apt install -y smartmontools ipmitool lm-sensors  # Debian/Ubuntu
sudo dnf install -y smartmontools ipmitool lm_sensors   # RHEL/CentOS

# Configure SMART monitoring for all disks
sudo smartctl --scan
sudo smartctl -a /dev/sda

# Enable SMART auto-testing
sudo smartctl -s on -s/consecutive/offline,/S,/T,60 /dev/sda

# Configure smartd daemon
cat > /etc/smartd.conf << 'SMARTD'
# Monitor all disks, report failures via mail, self-test daily
DEVICESCAN -d removable -n standby -m admin@example.com -M exec /usr/share/smartmontools/smartd-runner
/dev/sda -a -o on -S on -s (S/../.././02|L/../../6/03) -m admin@example.com
/dev/sdb -a -o on -S on -m admin@example.com
SMARTD

# Enable and start services
sudo systemctl enable --now smartd
sudo systemctl enable --now ipmi  # If BMC is available

# Test IPMI access
sudo ipmitool sdr
sudo ipmitool sensor list

Checkpoint: SMART monitoring is active, alerts are configured, and hardware sensors are accessible.


Implementation Patterns

Pattern 1: Cloud Instance Selection (BAD vs. GOOD)

BAD — Arbitrary instance selection without workload analysis

# ❌ BAD: Picking the cheapest instance without analyzing workload needs
# "Let's start with t3.medium and scale up if needed"
#
# Problems:
# - t3.medium is burstable (CPU credits), unreliable for databases
# - No I/O optimization for storage-heavy workloads
# - No consideration of ARM vs x86 for cost/performance
# - No cost analysis for long-running vs intermittent workloads

aws ec2 describe-instance-types \
  --filters "Name=instance-type,Values=t3.medium" \
  --query "InstanceTypes[0].InstanceType"

GOOD — Data-driven instance selection based on workload profiling

# Instance selection by workload type — reference guide
# Run as part of pre-provisioning checklist

cat > /etc/provisioning/workload-profiles.sh << 'PROFILE'
# Workload-to-instance mapping reference
# Usage: source workload-profiles.sh && get_profile database

get_profile() {
    local workload="$1"
    case "$workload" in
        database)
            echo "AWS family: r7i (memory-optimized)"
            echo "vCPU range: 8-64 | RAM/vCPU: 8-32GB | Storage: io2"
            echo "Network: 10Gbps | Burstable: No"
            echo "Recommended: r7i.xlarge (4 vCPU, 32GB) → r7i.2xlarge (8 vCPU, 64GB)"
            ;;
        web)
            echo "AWS family: m7i (general purpose)"
            echo "vCPU range: 4-32 | RAM/vCPU: 4-8GB | Storage: gp3"
            echo "Network: 5Gbps | Burstable: Yes (t3 for dev)"
            echo "Recommended: m7i.xlarge (4 vCPU, 16GB)"
            ;;
        compute)
            echo "AWS family: c7i (compute optimized)"
            echo "vCPU range: 8-128 | RAM/vCPU: 2-4GB | Storage: gp3"
            echo "Network: 10Gbps | Burstable: No"
            echo "Recommended: c7i.xlarge (4 vCPU, 8GB)"
            ;;
        batch)
            echo "AWS family: c7i (compute optimized) with spot"
            echo "vCPU range: 16-256 | RAM/vCPU: 2-4GB | Storage: gp3"
            echo "Network: 5Gbps | Burstable: Yes (spot-friendly)"
            echo "Recommended: c7i.2xlarge (8 vCPU, 16GB)"
            ;;
        storage)
            echo "AWS family: i7i (storage optimized)"
            echo "vCPU range: 8-64 | RAM/vCPU: 8-16GB | Storage: nvme-raid"
            echo "Network: 25Gbps | Burstable: No"
            echo "Recommended: i7i.2xlarge (8 vCPU, 64GB)"
            ;;
        *)
            echo "Unknown workload: $workload"
            echo "Available: database, web, compute, batch, storage"
            return 1
            ;;
    esac
}
PROFILE

# Source and use
source /etc/provisioning/workload-profiles.sh
get_profile database

Pattern 2: Cross-Architecture Deployment

# ❌ BAD: Assuming x86_64 everywhere
pip install some-package          # May not have ARM64 wheel
docker build -t myapp .           # May fail on ARM without multi-arch Dockerfile
apt install myapp-binary          # x86 binary won't run on ARM

# ✅ GOOD: Architecture-aware deployment
# Multi-architecture Dockerfile
cat > Dockerfile.multi << 'DOCKERFILE'
# syntax=docker/dockerfile:1
FROM --platform=$BUILDPLATFORM python:3.12-slim AS builder
WORKDIR /app
COPY requirements.txt .
RUN pip install --prefix=/install -r requirements.txt

FROM python:3.12-slim
WORKDIR /app
COPY --from=builder /install /usr/local
COPY . .
CMD ["python", "app.py"]
DOCKERFILE

# Build for both architectures
docker buildx build \
  --platform linux/amd64,linux/arm64 \
  -t myapp:latest \
  --push \
  .

# Architecture detection in provisioning scripts
ARCH=$(uname -m)
if [[ "$ARCH" == "x86_64" ]]; then
    PKG_ARCH="amd64"
elif [[ "$ARCH" == "aarch64" ]]; then
    PKG_ARCH="arm64"
else
    echo "Unsupported architecture: $ARCH" >&2
    exit 1
fi

Pattern 3: Hardware Inventory and Documentation

Bash — Complete hardware inventory script

#!/bin/bash
# Collect hardware inventory for change management documentation
# Usage: ./hardware-inventory.sh [--json] [--output /var/inventory/]
# Output: /var/inventory/<hostname>-YYYYMMDD-HHMMSS.json (or plain text)

set -euo pipefail

JSON_OUTPUT=false
OUTPUT_DIR="/var/inventory"

while [[ $# -gt 0 ]]; do
    case "$1" in
        --json) JSON_OUTPUT=true; shift ;;
        --output) OUTPUT_DIR="$2"; shift 2 ;;
        *) echo "Unknown option: $1"; exit 1 ;;
    esac
done

mkdir -p "$OUTPUT_DIR"

HOSTNAME=$(hostname)
TIMESTAMP=$(date +%Y%m%d-%H%M%S)
ISO_TIMESTAMP=$(date -Iseconds)

# CPU information
CPU_MODEL=$(grep 'model name' /proc/cpuinfo | head -1 | cut -d: -f2 | xargs)
CPU_ARCH=$(uname -m)
CPU_SOCKETS=$(nproc --all)
CPU_CORES=$(lscpu | awk '/^Core\(s\) per socket:/{print $4}')
CPU_THREADS=$(lscpu | awk '/^Thread\(s\) per core:/{print $4}')
CPU_COUNT=$((CPU_SOCKETS * CPU_CORES * CPU_THREADS))

# Memory information
MEM_TOTAL=$(awk '/^MemTotal:/{printf "%.0f", $2/1024/1024}' /proc/meminfo)
MEM_AVAIL=$(awk '/^MemAvailable:/{printf "%.0f", $2/1024/1024}' /proc/meminfo)
SWAP_TOTAL=$(awk '/^SwapTotal:/{printf "%.0f", $2/1024/1024}' /proc/meminfo)

# Storage inventory
STORAGE_JSON="["
FIRST=true
while IFS= read -r line; do
    DEV=$(echo "$line" | awk '{print $1}')
    SIZE=$(echo "$line" | awk '{print $2}')
    TYPE=$(echo "$line" | awk '{print $3}')
    MODEL=$(echo "$line" | awk '{$1=$2=$3=""; print}' | xargs)
    ROTA=$(cat /sys/block/$DEV/queue/rotational 2>/dev/null || echo "1")
    
    if [[ "$ROTA" == "0" ]]; then
        DISK_TYPE="ssd"
    else
        DISK_TYPE="hdd"
    fi
    
    if [[ "$FIRST" == "true" ]]; then
        FIRST=false
    else
        STORAGE_JSON+=","
    fi
    STORAGE_JSON+="{\"device\":\"/dev/$DEV\",\"size\":\"$SIZE\",\"type\":\"$DISK_TYPE\",\"model\":\"$MODEL\"}"
done < <(lsblk -dno NAME,SIZE,TYPE,MODEL | grep disk)
STORAGE_JSON+="]"

# Network interfaces
NETWORK_JSON="["
FIRST=true
for iface in $(ip -j link show | jq -r '.[].ifname' | grep -v lo); do
    SPEED=$(ethtool "$iface" 2>/dev/null | grep Speed | cut -d: -f2 | xargs || echo "unknown")
    
    if [[ "$FIRST" == "true" ]]; then
        FIRST=false
    else
        NETWORK_JSON+=","
    fi
    NETWORK_JSON+="{\"interface\":\"$iface\",\"speed\":\"$SPEED\"}"
done
NETWORK_JSON+="]"

# Kernel information
KERNEL=$(uname -r)

if [[ "$JSON_OUTPUT" == "true" ]]; then
    # Output as JSON for machine consumption
    cat << EOF
{
  "hostname": "$HOSTNAME",
  "timestamp": "$ISO_TIMESTAMP",
  "kernel": "$KERNEL",
  "cpu": {
    "model": "$CPU_MODEL",
    "architecture": "$CPU_ARCH",
    "sockets": $CPU_SOCKETS,
    "cores_per_socket": $CPU_CORES,
    "threads_per_core": $CPU_THREADS,
    "total_cpus": $CPU_COUNT
  },
  "memory": {
    "total_gb": $MEM_TOTAL,
    "available_gb": $MEM_AVAIL,
    "swap_total_gb": $SWAP_TOTAL
  },
  "storage": $STORAGE_JSON,
  "network": $NETWORK_JSON
}
EOF
else
    # Human-readable output
    echo "=== Hardware Inventory: $HOSTNAME ==="
    echo "Timestamp: $ISO_TIMESTAMP"
    echo "Kernel:    $KERNEL"
    echo ""
    echo "--- CPU ---"
    echo "  Model:     $CPU_MODEL"
    echo "  Architecture: $CPU_ARCH"
    echo "  Sockets:   $CPU_SOCKETS"
    echo "  Cores/Socket: $CPU_CORES"
    echo "  Threads/Core: $CPU_THREADS"
    echo "  Total CPUs: $CPU_COUNT"
    echo ""
    echo "--- Memory ---"
    echo "  Total:    ${MEM_TOTAL}GB"
    echo "  Available: ${MEM_AVAIL}GB"
    echo "  Swap:     ${SWAP_TOTAL}GB"
    echo ""
    echo "--- Storage ---"
    lsblk -dno NAME,SIZE,TYPE,MODEL,ROTA | grep disk | while read -r dev size type model rota; do
        if [[ "$rota" == "0" ]]; then
            dtype="SSD"
        else
            dtype="HDD"
        fi
        echo "  /dev/$dev  $size  $dtype  ($model)"
    done
    echo ""
    echo "--- Network ---"
    for iface in $(ip -j link show | jq -r '.[].ifname' | grep -v lo); do
        speed=$(ethtool "$iface" 2>/dev/null | grep Speed | cut -d: -f2 | xargs || echo "unknown")
        echo "  $iface  speed=$speed"
    done
fi

# Save to file
OUTPUT_FILE="$OUTPUT_DIR/${HOSTNAME}-${TIMESTAMP}.json"
mkdir -p "$OUTPUT_DIR"
cat << EOF > "$OUTPUT_FILE"
{
  "hostname": "$HOSTNAME",
  "timestamp": "$ISO_TIMESTAMP",
  "kernel": "$KERNEL",
  "cpu": {
    "model": "$CPU_MODEL",
    "architecture": "$CPU_ARCH",
    "sockets": $CPU_SOCKETS,
    "cores_per_socket": $CPU_CORES,
    "threads_per_core": $CPU_THREADS,
    "total_cpus": $CPU_COUNT
  },
  "memory": {
    "total_gb": $MEM_TOTAL,
    "available_gb": $MEM_AVAIL,
    "swap_total_gb": $SWAP_TOTAL
  },
  "storage": $STORAGE_JSON,
  "network": $NETWORK_JSON
}
EOF
echo "Inventory saved to $OUTPUT_FILE"

Constraints

MUST DO

  • MUST analyze workload requirements before selecting hardware — match CPU, memory, storage I/O, and network capacity to actual needs
  • MUST document all hardware specifications, RAID configurations, and network assignments in a change management system
  • MUST configure RAID based on durability requirements — critical data gets RAID 1/5/6/10, non-critical gets cheaper alternatives
  • MUST verify SSD TRIM support and enable periodic fstrim — prevents SSD performance degradation over time
  • MUST monitor SMART health on all storage devices and set up alerting for predictive failure indicators
  • MUST account for 20-30% capacity overhead — never provision to 100% utilization; leave headroom for growth and burst
  • MUST verify cross-architecture compatibility when deploying software across x86_64 and ARM64 environments

MUST NOT DO

  • MUST NOT use RAID 5 for databases or write-heavy workloads — RAID 5 write penalty (4 I/Os per write) severely degrades performance
  • MUST NOT provision to maximum capacity — always maintain 20-30% headroom for growth, failover, and burst
  • MUST NOT use burstable instances (t3, m5b) for databases or consistently heavy workloads — CPU credit exhaustion causes latency spikes
  • MUST NOT mix HDD and SSD in the same RAID array — all drives operate at the speed of the slowest drive
  • MUST NOT use RAID 0 for any production data — zero redundancy means any drive failure loses all data
  • MUST NOT select cloud instances based solely on price — total cost of ownership includes storage I/O costs, network egress fees, and performance penalties

Related Skills

SkillPurpose
kernel-tuningTune kernel parameters after hardware is provisioned for optimal performance
resource-managementAllocate resources to workloads on the provisioned hardware
storage-architectureConfigure filesystems, LVM, and mount options on provisioned storage
linux-securityHarden the provisioned system against security threats
observabilityMonitor hardware health and set up alerting for failures

Live References