L’interface est localisée ; les présentations et documents des Skills sont traduits automatiquement par IA dans votre langue. Le code, les commandes, chemins et termes techniques restent en version originale, et le document de l’auteur fait foi.
Explorer les Skills
Données et recherche · SKILL.md

msa-gauge-rr

msa-gauge-rr

Measurement System Analysis (MSA) and Gauge Repeatability & Reproducibility (Gauge R&R) — plan, execute, and interpret an MSA study for variable or attribute measurement systems. Use when qualifying a gauge for a new part, validating a measurement system before PPAP, interpreting Gauge R&R results, or auditing MSA studies for adequacy. Covers AIAG MSA 4th e…

Independent GitHub snapshot · Automated classification · Original documentation governs

Documentation de la Skill

GitHub

name: msa-gauge-rr description: >- Measurement System Analysis (MSA) and Gauge Repeatability & Reproducibility (Gauge R&R) — plan, execute, and interpret an MSA study for variable or attribute measurement systems. Use when qualifying a gauge for a new part, validating a measurement system before PPAP, interpreting Gauge R&R results, or auditing MSA studies for adequacy. Covers AIAG MSA 4th edition. license: MIT metadata: author: RBraga01 version: "1.1" iso-9001: "7.1.5" iatf-16949: "7.1.5.1, 7.1.5.2" aiag-reference: "AIAG MSA 4th Edition" domain: quality-engineering subdomain: measurement industries: automotive,electronics,aerospace,medical,general status: approved created: "2026-06-06" last_updated: "2026-06-06" updated_by: migmcc reviewed_by: RBraga01 standard_edition: "AIAG MSA 4th Edition (2010)"

Measurement System Analysis (MSA) / Gauge R&R

When to use

Use this skill when:

  • Qualifying a measurement system for a new part or process (PPAP requirement)
  • Interpreting Gauge R&R results — is this gauge acceptable?
  • Auditing a supplier's MSA study for correctness and adequacy
  • Selecting the right study type for a given measurement situation
  • Investigating a quality problem where measurement error may be a factor
  • Responding to a customer request for MSA data on a specific characteristic

Prerequisites

  • The characteristic to be measured (product or process)
  • The gauge or measurement system to be studied
  • Production parts spanning the expected process variation (10 parts minimum)
  • At least 2 trained appraisers who normally perform the measurement
  • The specification (tolerance) for the characteristic

Workflow

Step 1 — Select the MSA study type

Study typeWhen to use
Gauge R&R (crossed)Variable data, 2–3 appraisers, each measures all parts (most common)
Gauge R&R (nested)Variable data, parts are destroyed during measurement (e.g., tensile test)
Attribute MSAPass/fail, go/no-go, visual inspection — data is not a number
Bias studyAccuracy of a single gauge vs. a reference standard
Linearity studyWhether gauge accuracy is consistent across its measurement range
Stability studyWhether gauge accuracy drifts over time

For PPAP: Crossed Gauge R&R is required for all variable gauges on special characteristics.


Step 2 — Crossed Gauge R&R study procedure

Setup:

  • Minimum 10 parts selected to represent the full process variation range (not cherry-picked from centre of tolerance)
  • Minimum 2 appraisers (3 preferred)
  • Minimum 2 trials per appraiser per part (3 preferred)
  • Parts randomly numbered and labelled — appraisers must not see each other's measurements
  • Measurement conditions must match normal production conditions

Standard study design:

  • 10 parts × 3 appraisers × 2 trials = 60 measurements
  • 10 parts × 2 appraisers × 3 trials = 60 measurements

Execution:

  1. Appraiser A measures all 10 parts in random order — record results
  2. Appraiser B measures all 10 parts in random order — record results
  3. Appraiser C measures all 10 parts in random order — record results
  4. Repeat the cycle for trial 2 (and trial 3 if applicable)
  5. Appraisers must not see their own previous results or other appraisers' results during the study

Do NOT:

  • Allow appraisers to adjust the gauge between trials
  • Use parts that are all near the nominal value (no spread)
  • Record only one trial (single measurement per appraiser per part is insufficient)

Step 3 — Interpret the results

%GRR (Gauge R&R as % of Total Variation or % of Tolerance)

%GRRInterpretationDecision
< 10%Excellent✅ Gauge accepted
10% – 30%Marginal⚠️ May be acceptable based on application — requires engineering review and customer approval
> 30%Unacceptable❌ Gauge not suitable — investigate and improve before use in production

Two calculation methods:

  • % of Study Variation (% of TV): GRR / Total Variation × 100 — preferred when process is in control
  • % of Tolerance: GRR / Tolerance × 100 — use when process capability is unknown or for attribute gauging

For PPAP, %GRR < 30% (tolerance method) is the typical customer acceptance criterion. <10% is the target.

Number of Distinct Categories (ndc)

ndc = 1.41 × (Part Variation / GRR)

ndcInterpretation
≥ 5✅ Gauge can distinguish adequate number of categories
3 – 4⚠️ Gauge can be used for go/no-go decisions only
1 – 2❌ Gauge cannot distinguish parts — unacceptable

ndc ≥ 5 is required for measurement systems used on special characteristics.

Repeatability vs. Reproducibility

ComponentDescriptionCommon cause
EV (Equipment Variation / Repeatability)Variation when same appraiser measures same part multiple timesGauge imprecision, worn parts, environment
AV (Appraiser Variation / Reproducibility)Variation between different appraisers measuring the same partTraining inconsistency, measurement technique, gauge setup

If EV > AV: investigate gauge (calibration, maintenance, resolution) If AV > EV: investigate training, measurement procedure, gauge fixture/setup

When %GRR > 30% — improving the measurement system

A result >30% means the gauge is not suitable for production use. Do not proceed to PPAP — investigate and retest. Common root causes and actions:

Root cause (high EV)Action
Gauge resolution too coarseReplace with a gauge of finer resolution (rule: resolution ≤ 10% of tolerance)
Gauge worn or damagedInspect, recalibrate, or replace the gauge
Environmental interference (vibration, temperature)Move measurement to a stable environment; add fixture if needed
Inconsistent part fixturingDesign a repeatable fixture or measurement aid
Root cause (high AV)Action
Measurement technique varies by appraiserDevelop a standardised measurement instruction (WI with photos/video)
Gauge difficult to read or positionRedesign fixture; add a datum locator; use a self-positioning gauge
Training gapRetrain all appraisers using the standardised measurement WI; repeat the study

After implementing improvements: re-run the full study. Do not accept a %GRR > 30% result with a customer waiver unless the characteristic is non-critical and the customer explicitly agrees in writing.


Step 4 — Attribute MSA (pass/fail gauges)

For go/no-go gauges, visual inspection, and any pass/fail decision:

Expanded attribute study (recommended for PPAP):

  • 50 parts spanning the full range (include parts near the accept/reject boundary)
  • 3 appraisers × 3 trials per part = 450 measurements
  • Calculate % agreement (within appraiser and between appraisers)
  • Calculate kappa statistic (Cohen's kappa ≥ 0.9 is acceptable)

Short method (minimum acceptable):

  • 20 parts × 2 appraisers × 2 trials
  • 90% agreement within and between appraisers required
  • Include borderline parts near the specification limit

Step 5 — Audit an existing MSA study

When reviewing a supplier's or internal MSA, check:

  • Parts selected represent the full process variation range (not all near nominal)
  • Minimum 10 parts, 2 appraisers, 2 trials confirmed
  • Appraisers did not see each other's or their own previous results
  • %GRR result stated clearly (tolerance method or study variation method — which one?)
  • ndc ≥ 5 for all special characteristics
  • EV vs. AV breakdown analysed and interpreted
  • %GRR < 30% (conditional: <10% preferred)
  • For attribute gauges: kappa statistic calculated
  • Study performed in production conditions (not in metrology lab if production measurement is on the line)
  • Gauge calibration certificate current at time of study

Validation criteria

An MSA study is acceptable for PPAP when:

  • %GRR < 30% (tolerance method) — <10% preferred
  • ndc ≥ 5
  • Study conducted with production appraisers using production gauges in production conditions
  • Parts selected from the full process variation range
  • Results documented with part numbers, appraiser IDs, gauge ID, and calibration reference

Common mistakes

  • Parts selected near the nominal value only — artificially inflates ndc and understates GRR
  • Appraiser A re-measures all parts immediately — not the same as separate trials (must separate in time)
  • Using metrology lab gauges for an MSA of a production line gauge — study must use the same gauge in the same conditions
  • %GRR > 30% submitted in PPAP without explanation or customer waiver
  • Gauge calibration expired at time of MSA study — study is invalid
  • ndc < 5 on a special characteristic — automatic PPAP finding in IATF audits
  • Attribute MSA with only 2 appraisers and no borderline parts — study has no discriminating power

Output Format

At the start of each use, ask the user:

"How would you like to receive the output? A — Structured Markdown (formatted tables and sections, ready to copy) B — Plain tables (simplified structure for Excel or Word) C — Narrative report (flowing text for a formal document or email)

Default: A."

Adapt all output sections to the chosen format. If the platform or session context already defines a format preference, skip this question.

Changelog

VersionDateAuthorChange
1.02026-06-06@RBraga01Initial release
1.12026-06-06@migmccAdded improvement guidance for %GRR > 30% — root cause table for high EV and high AV with corrective actions
Skills enregistrées