L’interface est localisée ; les présentations et documents des Skills sont traduits automatiquement par IA dans votre langue. Le code, les commandes, chemins et termes techniques restent en version originale, et le document de l’auteur fait foi.
Explorer les Skills
Productivité · SKILL.md

bio-read-qc-quality-filtering

bio-read-qc-quality-filtering

Filters reads by quality, length, N content, and complexity with Trimmomatic, fastp, and Cutadapt, including sliding-window trimming, per-read unqualified-base filtering, and 2-color poly-G removal. Use when reads have poor-quality tails, when an assembly or k-mer workflow needs clean input, or when a junk read subpopulation must be dropped. For adapter rem…

Independent GitHub snapshot · Automated classification · Original documentation governs

Documentation de la Skill

GitHub

name: bio-read-qc-quality-filtering description: Filters reads by quality, length, N content, and complexity with Trimmomatic, fastp, and Cutadapt, including sliding-window trimming, per-read unqualified-base filtering, and 2-color poly-G removal. Use when reads have poor-quality tails, when an assembly or k-mer workflow needs clean input, or when a junk read subpopulation must be dropped. For adapter removal use adapter-trimming; for all-in-one preprocessing use fastp-workflow. tool_type: cli primary_tool: trimmomatic

Version Compatibility

Reference examples tested with: Trimmomatic 0.39+, fastp 0.23+, Cutadapt 4.4+

Before using code patterns, verify installed versions match. If versions differ:

  • CLI: <tool> --version then <tool> --help to confirm flags

If code throws ImportError, AttributeError, or TypeError, introspect the installed package and adapt the example to match the actual API rather than retrying.

Quality Filtering -- trim lightly or not at all, and never without a length filter

Trim low-quality bases and drop low-quality reads with Trimmomatic (sliding window / MAXINFO), fastp (per-read filter + window cut), or Cutadapt (BWA-style quality trim).

"Filter reads by quality" -> Remove low-quality bases and/or discard reads below quality/length thresholds.

  • CLI: fastp -i in.fq -o out.fq --cut_right -q 20 -l 36 (window trim + per-read filter + length gate)
  • CLI: trimmomatic SE in.fq out.fq SLIDINGWINDOW:4:20 MINLEN:36

Scope: this skill OWNS quality/length/N/complexity filtering. Adapter removal -> read-qc/adapter-trimming. Single-pass trim+QC -> read-qc/fastp-workflow. Reading the quality plots -> read-qc/quality-reports. OUT OF SCOPE: contamination removal (read-qc/contamination-screening).

The Single Most Important Modern Insight

  1. Modern local aligners SOFT-CLIP low-quality tails, so quality trimming is usually unnecessary -- and AGGRESSIVE quality trimming actively harms downstream results. Williams 2016 showed aggressive trimming changed expression estimates for >10% of genes; Del Fabbro 2013 showed stringent Q>30 DEGRADES de novo assembly; MacManes 2014 found gentle trimming (remove only Phred<2-5) optimal for RNA-seq; GATK discourages quality trimming because BQSR recalibrates qualities itself. Trim ADAPTER always (read-qc/adapter-trimming); quality-trim lightly or not at all before a soft-clipping aligner. The workflows that genuinely need quality trimming are assembly, k-mer/pseudo-alignment, small-RNA, amplicon, and variant calling WITHOUT BQSR.

  2. Quality FILTERING (drop whole reads) and quality TRIMMING (cut bases within a read) are different operations with different tools. fastp's -q/-u/-n filters whole reads by the fraction of unqualified bases; --cut_right / Trimmomatic SLIDINGWINDOW trims bases from a window scan. Filtering removes a junk subpopulation (a low-Q hump in the per-sequence-quality plot); trimming shortens reads with decayed tails. Choose by whether the problem is some bad reads or bad ends.

  3. A short post-trim read mis-maps, so quality trimming MUST be paired with a minimum-length filter. Williams 2016 showed that adding a post-trim min-length filter mitigates most of the expression distortion that trimming introduces, because over-trimmed fragments that would map spuriously are dropped instead. MINLEN (Trimmomatic, always last), -l (fastp), -m (cutadapt) are not optional add-ons; they are the safety mechanism that makes trimming safe.

Two-color note: on NextSeq/NovaSeq the quality scores are binned to four values (RTA3: 2, 12, 23, 37), so a sliding-window threshold like 4:15 partitions between the 12 and 23 bins rather than acting on a smooth gradient -- thresholds tuned on HiSeq-era 0-40 qualities behave differently. And poly-G tails are HIGH quality, so a quality filter does not remove them (use poly-G trimming).

Tool Taxonomy

ToolMechanismWhen it wins
fastpPer-read unqualified-base filter (-q/-u/-n) + window cut (--cut_right) + auto poly-GDEFAULT; one fast pass, filtering and trimming together
TrimmomaticSLIDINGWINDOW / MAXINFO window trim; ordered step pipeline; orphan handlingLegacy/reproducibility pipelines; MAXINFO length-vs-quality balance
Cutadapt-q BWA running-sum quality trim (combined with adapter removal)When already running cutadapt for adapters; precise per-end control

Decision Tree by Scenario

WorkflowQuality trimmingWhy
Alignment-based DNA/RNA (BWA-MEM, STAR, Bowtie2 local, HISAT2)Light or noneAligner soft-clips tails; aggressive trim distorts expression
GATK variant calling with BQSRNoneBQSR recalibrates; trimming interferes
De novo assemblyModerate (~Q20) + min-lengthLow-Q errors corrupt the de Bruijn graph; stringent Q>30 over-trims
k-mer / pseudo-alignment (kallisto/salmon)Light + adapterErrors create phantom k-mers
A junk read subpopulation (bimodal per-seq quality)FILTER whole reads (-e/AVGQUAL)Trimming cannot fix a globally bad read
Variant calling WITHOUT BQSRModerate + min-lengthNo recalibration safety net

Default when uncertain: trim adapter, apply a light window trim plus a minimum-length filter, then confirm with FastQC.

Trimmomatic

Steps run in COMMAND-LINE ORDER; put quality steps before MINLEN so the length check reflects all trimming.

# Single-end: light leading/trailing + window, length-gated
trimmomatic SE -phred33 in.fq.gz out.fq.gz \
    LEADING:3 TRAILING:3 SLIDINGWINDOW:4:20 MINLEN:36

# Paired-end (four outputs: paired + orphan)
trimmomatic PE -phred33 -threads 8 \
    R1.fq.gz R2.fq.gz \
    R1_paired.fq.gz R1_unpaired.fq.gz R2_paired.fq.gz R2_unpaired.fq.gz \
    SLIDINGWINDOW:4:20 MINLEN:36

# MAXINFO: adaptive length-vs-quality balance (strictness <0.2 favors length, >0.8 favors correctness)
trimmomatic SE in.fq.gz out.fq.gz MAXINFO:40:0.5 MINLEN:36
StepMeaning
SLIDINGWINDOW:W:Qscan 5'->3'; cut from the point where the W-bp window mean drops below Q
MAXINFO:L:Sadaptive trim balancing target length L against error rate; strictness S in 0-1
LEADING:Q / TRAILING:Qcut 5'/3' bases below Q (also removes N)
MINLEN:L / AVGQUAL:QDROP read if shorter than L / if mean quality below Q
CROP:L / HEADCROP:Ncap length / remove first N bases (do NOT HEADCROP random-hexamer bias -- see below)

Do NOT HEADCROP the first ~12 bp of RNA-seq to "fix" the wavy per-base-content plot: that pattern is random-hexamer priming bias (Hansen 2010), not adapter, and trimming it just discards real data without removing the underlying bias.

fastp

fastp separates per-read FILTERING from window TRIMMING. Quality filtering is on by default (-q 15).

# Per-read quality filter: base < Q20 is 'unqualified'; drop read if >40% unqualified or >5 Ns
fastp -i in.fq.gz -o out.fq.gz -q 20 -u 40 -n 5 -l 36

# Window trim from the 3' (Trimmomatic SLIDINGWINDOW analogue) + length gate
fastp -i R1.fq.gz -I R2.fq.gz -o R1.fq.gz -O R2.fq.gz \
      --cut_right --cut_window_size 4 --cut_mean_quality 20 -l 36

# Drop globally low-quality reads by mean quality (filter, not trim)
fastp -i in.fq.gz -o out.fq.gz -e 25

# 2-color poly-G (auto-enabled for NextSeq/NovaSeq from the instrument ID)
fastp -i in.fq.gz -o out.fq.gz --trim_poly_g

# Low-complexity filter (e.g. poly-A / homopolymer-rich reads)
fastp -i in.fq.gz -o out.fq.gz --low_complexity_filter --complexity_threshold 30

fastp flags: -q qualified quality (default 15), -u unqualified percent limit (default 40), -n N base limit (default 5), -e average-quality filter (default 0 = off), -l length required (default 15), --length_limit max length (long form only), --cut_front/--cut_tail/--cut_right window cut modes (off by default), --cut_window_size (4), --cut_mean_quality (Q20).

Cutadapt

-q uses the BWA running-partial-sum algorithm, not a fixed cutoff, so a single high-Q base inside a low-Q run does not stop trimming. Quality trimming runs BEFORE adapter removal.

# 3'-only quality trim with a length gate (5',3' form: -q 15,20)
cutadapt -q 20 -m 36 -o out.fq.gz in.fq.gz

# Combined adapter + light quality trim, paired
cutadapt -a AGATCGGAAGAGC -A AGATCGGAAGAGC -q 20 -m 36 \
         -o R1.fq.gz -p R2.fq.gz R1.fq.gz R2.fq.gz

Quantitative Thresholds

ParameterTypicalRationale
Window qualityQ20 (4:20)1% error; light. Aggressive (Q25-30) distorts expression/assembly (Williams 2016, Del Fabbro 2013)
fastp -q / -uQ15 / 40%fastp defaults; a base under Q15 is unqualified, read dropped if >40% unqualified
MINLEN / -l / -m36 (150 bp reads)Mandatory after trimming; short reads mis-map. Scale up for longer inserts
complexity_threshold30 (30%)fastp default for low-complexity filtering
MAXINFO strictness0.2-0.8<0.2 favors length, >0.8 favors correctness

Common Errors

SymptomCauseSolution
Expression estimates shift for many genesAggressive quality trimmingTrim lightly; always add a min-length filter (Williams 2016)
Variant calling worse after trimmingTrimmed before/around BQSRDo not quality-trim for GATK BQSR workflows
Window threshold behaves oddly on NovaSeqBinned quality (4 values) makes windows coarseExpect step-like behavior; do not port HiSeq thresholds blindly
Reads mis-map after trimmingNo min-length filter, over-trimmed fragmentsAdd MINLEN / -l / -m
Poly-G tails survive quality filteringPoly-G is high quality on 2-colorUse --trim_poly_g / cutadapt --nextseq-trim
R1/R2 out of syncIndependent SE trimming of matesUse Trimmomatic paired outputs or fastp/cutadapt paired mode

References

Bolger AM, Lohse M, Usadel B. 2014. Trimmomatic: a flexible trimmer for Illumina sequence data. Bioinformatics 30(15):2114-2120. Chen S, Zhou Y, Chen Y, Gu J. 2018. fastp: an ultra-fast all-in-one FASTQ preprocessor. Bioinformatics 34(17):i884-i890. MacManes MD. 2014. On the optimal trimming of high-throughput mRNA sequence data. Frontiers in Genetics 5:13. Del Fabbro C, Scalabrin S, Morgante M, Giorgi FM. 2013. An extensive evaluation of read trimming effects on Illumina NGS data analysis. PLoS ONE 8(12):e85024. Williams CR, Baccarella A, Parrish JZ, Kim CC. 2016. Trimming of sequence reads alters RNA-Seq gene expression estimates. BMC Bioinformatics 17:103. Hansen KD, Brenner SE, Dudoit S. 2010. Biases in Illumina transcriptome sequencing caused by random hexamer priming. Nucleic Acids Research 38(12):e131.

Related Skills

read-qc/adapter-trimming - Remove adapter before quality filtering read-qc/quality-reports - Read the quality plots that motivate filtering read-qc/fastp-workflow - All-in-one preprocessing in a single pass read-alignment/bwa-alignment - Soft-clipping aligner that absorbs low-quality tails read-alignment/star-alignment - Soft-clipping RNA aligner (light trimming preferred)