L’interface est localisée ; les présentations et documents des Skills sont traduits automatiquement par IA dans votre langue. Le code, les commandes, chemins et termes techniques restent en version originale, et le document de l’auteur fait foi.
Explorer les Skills
Documents · SKILL.md

hazardous-waste-manifest

hazardous-waste-manifest

Drafts a Uniform Hazardous Waste Manifest (EPA Form 8700-22) compliant with RCRA, EPA, and DOT requirements. Assembles generator, transporter, and TSDF chain-of-custody data with 40 CFR Parts 261–265 waste coding, DOT classification under 49 CFR Parts 171–180, certification language, and discrepancy reporting. Use when preparing manifest packages for hazard…

Independent GitHub snapshot · Automated classification · Original documentation governs

Documentation de la Skill

GitHub

name: hazardous-waste-manifest language: en description: Drafts a Uniform Hazardous Waste Manifest (EPA Form 8700-22) compliant with RCRA, EPA, and DOT requirements. Assembles generator, transporter, and TSDF chain-of-custody data with 40 CFR Parts 261–265 waste coding, DOT classification under 49 CFR Parts 171–180, certification language, and discrepancy reporting. Use when preparing manifest packages for hazardous waste shipments, RCRA tracking documents, or waste disposal compliance filings. tags:

  • drafting
  • regulatory

Hazardous Waste Manifest (EPA Form 8700-22)

Drafts a RCRA-compliant Uniform Hazardous Waste Manifest establishing chain of custody from generation through final disposal.

Prerequisites

  1. Generator EPA ID — 40 CFR Part 262 registration; physical site address
  2. Transporter records — EPA ID, DOT registration, permit status per carrier
  3. TSDF authorization — facility EPA ID, state permits confirming acceptance of waste type/quantity
  4. Waste characterization — DOT proper shipping name, EPA waste codes (40 CFR Part 261), quantity, container count/type, hazard class, packing group
  5. Emergency contact — 24-hour number (CHEMTREC or company line)

Output Structure

1. Generator Information

FieldRequirement
Legal business nameFull legal name
Generation site addressPhysical (not mailing)
EPA ID number40 CFR Part 262
Primary contact phoneBusiness hours
24-hour emergency contactRequired for transport incidents

2. Transporter Information (repeat per carrier)

FieldRequirement
Company legal nameAs registered with EPA
EPA ID number40 CFR Part 263
DOT registration number49 CFR Parts 171–180
Signature/date blockCustody receipt acknowledgment

3. Designated Facility (TSDF)

FieldRequirement
Facility legal nameAs permitted
EPA ID numberCurrent registration
State permit numbersDTSC or equivalent state authority
Permitted waste typesMust align with manifest waste codes

Verify TSDF authorization for specific waste type/quantity and LDR treatment standard compliance before designating.

4. Waste Description

FieldRequirement
DOT proper shipping name49 CFR Part 172
EPA hazardous waste codesFour-digit codes, 40 CFR Part 261
QuantityWeight AND volume
Container type and countDOT-approved specs
Physical/chemical formSolid, liquid, sludge, etc.
Hazard class / packing groupDOT classification
Special handlingIf applicable

5. Certifications

  • Emergency number: CHEMTREC (1-800-424-9300) or company line
  • Generator certification (verbatim per 40 CFR 262.23):
I hereby declare that the contents of this consignment are fully and
accurately described above by the proper shipping name, and are classified,
packed, marked and labeled/placarded, and are in all respects in proper
condition for transport according to applicable international and national
governmental regulations. If export shipment and I am the Primary Exporter,
I certify that the contents of this consignment conform to the terms of the
attached EPA Acknowledgment of Consent.
  • Include waste minimization certification: volume/toxicity reduction program in place, disposal method minimizes health/environmental threats

6. Signatures & Discrepancy Reporting

Signature chain: generator representative → each transporter → receiving facility operator (each with date)

Discrepancy fields per 40 CFR 264.72 / 265.72:

  • Quantity variation (significant vs. non-significant)
  • Container damage or count mismatch
  • Waste type or description discrepancy
  • Unacceptable waste notation
  • Facility irregularity documentation

7. Copy Distribution

  1. Generator retained copy
  2. One copy per transporter
  3. Designated facility (TSDF)
  4. Return copy to generator as delivery/disposal proof

Guidelines

  • Final document must conform to EPA Uniform Manifest format (40 CFR Part 262, Subpart B)
  • State overlays: CA, NY, and others require state-specific forms or additional fields — check state environmental agency requirements
  • Multi-transporter: each carrier needs a separate signed acknowledgment block; verify current EPA and DOT credentials
  • LDR: confirm TSDF is authorized for applicable land disposal restriction treatment standards
  • Discrepancy threshold: significant quantity discrepancies trigger EPA regional office notification — flag for attorney review
  • Retention: generator must retain copies minimum 3 years per 40 CFR 262.40 [VERIFY against recent RCRA amendments]
Skills enregistrées