L’interface est localisée ; les présentations et documents des Skills sont traduits automatiquement par IA dans votre langue. Le code, les commandes, chemins et termes techniques restent en version originale, et le document de l’auteur fait foi.
Explorer les Skills
Données et recherche · SKILL.md

curing-steps

curing-steps

Configure 4-step curing analysis (vis, rub, glassy, sp) in Abaqus. Invoke when user needs curing step sequence, static step settings, or step-by-step curing process setup.

Independent GitHub snapshot · Automated classification · Original documentation governs

Documentation de la Skill

GitHub

name: "curing-steps" description: "Configure 4-step curing analysis (vis, rub, glassy, sp) in Abaqus. Invoke when user needs curing step sequence, static step settings, or step-by-step curing process setup."

Curing Steps Analysis

Description

Configure 4-step curing analysis (vis, rub, glassy, sp) in Abaqus. Invoke when user needs curing step sequence, static step settings, or step-by-step curing process setup.

Content

The composite curing simulation uses 4 steps in sequence, all defined as *Static steps with nlgeom=NO.

Step Sequence

Step 1: vis (viscous state)

  • Increment control: 0.1, 1., 1e-05, 0.5
  • Temperature: 150°C
  • Pressure: 0.6 MPa
  • Friction: 0.45
  • Tool BC: U1=0, U2=0

Step 2: rub (rubbery state)

  • Increment control: 0.1, 1., 1e-05, 0.3
  • Temperature: 180°C
  • Pressure: 0.6 MPa
  • Friction: 0.2 (taumax=0.55)
  • Tool BC: continues from vis step

Step 3: glassy (glassy state)

  • Increment control: 0.1, 1., 1e-05, 0.5
  • Temperature: 25°C
  • Pressure: No pressure
  • Friction: 0.169
  • Tool BC: continues from rub step

Step 4: sp (springback)

  • Increment control: 0.1, 1., 1e-05, 0.5
  • Temperature: 25°C
  • Pressure: No pressure
  • BC: Set-2 U1=U2=U3=0
  • Model Change: removes contact + tool

Static Step Format

The *Static step uses the following format with initial increment, total time, min increment, and max increment:

*Static
initial_increment, total_time, min_increment, max_increment

Example for vis step:

*Static
0.1, 1., 1e-05, 0.5

Output Requests Per Step

Each step includes the following output requests:

*Output, field
*Node Output
CF, NT, RF, U
*Element Output, directions=YES
LE, PE, PEEQ, PEMAG, S, SDV, TEMP
*Contact Output
CDISP, CSTRESS
*Output, history, variable=PRESELECT

Restart Configuration

No restart output is written:

*Restart, write, frequency=0

Step Transitions

Loads and boundary conditions carry forward from one step to the next unless explicitly replaced with op=NEW. This means:

  • Tool BCs applied in the vis step remain active through the glassy step
  • Pressure applied in vis/rub steps is carried forward unless removed
  • To replace all previous loads/BCs, use op=NEW on the load or BC keyword