L’interface est localisée ; les présentations et documents des Skills sont traduits automatiquement par IA dans votre langue. Le code, les commandes, chemins et termes techniques restent en version originale, et le document de l’auteur fait foi.
Explorer les Skills
Développement · SKILL.md

iso10993-evaluator

iso10993-evaluator

Biological evaluation planning skill implementing ISO 10993-1 for biocompatibility testing strategy

Independent GitHub snapshot · Automated classification · Original documentation governs

Documentation de la Skill

GitHub

name: iso10993-evaluator description: Biological evaluation planning skill implementing ISO 10993-1 for biocompatibility testing strategy allowed-tools:

  • Read
  • Write
  • Glob
  • Grep
  • Edit
  • Bash metadata: specialization: biomedical-engineering domain: science category: Biocompatibility and Materials skill-id: BME-SK-016 graph: domains: [domain:biomedical-engineering] skillAreas: [skill-area:statistical-analysis, skill-area:data-analysis, skill-area:compliance-automation] workflows: [workflow:experiment-design, workflow:peer-review-cycle] roles: [role:biomedical-engineer, role:lab-technician]

ISO 10993 Evaluator Skill

Purpose

The ISO 10993 Evaluator Skill supports biological evaluation planning per ISO 10993-1, determining biocompatibility testing requirements based on device categorization, contact type, and duration.

Capabilities

  • Device categorization (body contact, duration)
  • Testing endpoint determination matrix
  • Existing data evaluation guidance
  • Equivalence assessment templates
  • Gap analysis for testing requirements
  • Biological evaluation plan generation
  • Report template generation
  • Risk-based testing strategy
  • Alternative testing approaches
  • Literature review guidance
  • Toxicological risk assessment support

Usage Guidelines

When to Use

  • Planning biocompatibility testing programs
  • Evaluating existing biocompatibility data
  • Assessing material equivalence
  • Preparing biological evaluation reports

Prerequisites

  • Device materials identified
  • Contact type and duration defined
  • Manufacturing process documented
  • Existing data compiled

Best Practices

  • Apply risk-based approach per ISO 10993-1:2018
  • Evaluate existing data before new testing
  • Consider material equivalence carefully
  • Document rationale for testing decisions

Process Integration

This skill integrates with the following processes:

  • Biological Evaluation Planning (ISO 10993)
  • Extractables and Leachables Analysis
  • Biomaterial Selection and Characterization
  • 510(k) Premarket Submission Preparation

Dependencies

  • ISO 10993 series standards
  • FDA G95-1 guidance
  • Material databases
  • Testing laboratory capabilities
  • Toxicological databases

Configuration

iso10993-evaluator:
  contact-categories:
    - surface-device
    - external-communicating
    - implant
  contact-types:
    - skin
    - mucosal-membrane
    - breached-surface
    - blood-path-indirect
    - tissue-bone
    - blood
  duration-categories:
    - limited
    - prolonged
    - permanent

Output Artifacts

  • Device categorization documents
  • Testing requirement matrices
  • Biological evaluation plans
  • Gap analysis reports
  • Equivalence assessments
  • BER templates
  • Literature review summaries
  • Testing rationale documents

Quality Criteria

  • Categorization follows ISO 10993-1:2018
  • Testing endpoints appropriate for device
  • Existing data properly evaluated
  • Equivalence arguments supported
  • Gap analysis comprehensive
  • Documentation supports regulatory review
Skills enregistrées