on-prem-infrastructure

on-prem-infrastructure

Engineers on-premises infrastructure including IPMI/iLO/iDRAC remote management, PXE deployment, network storage (NFS/iSCSI/FC), multipath I/O, and datacenter physical operations for bare-metal Linux systems.

Independent GitHub snapshot · Automated classification · Original documentation governs

Documentación de la Skill

GitHub

name: on-prem-infrastructure description: Engineers on-premises infrastructure including IPMI/iLO/iDRAC remote management, PXE deployment, network storage (NFS/iSCSI/FC), multipath I/O, and datacenter physical operations for bare-metal Linux systems. license: MIT compatibility: opencode metadata: version: "1.0.0" domain: linux triggers: IPMI, iLO, iDRAC, PXE boot, iSCSI, multipath, bare-metal provisioning, datacenter rack archetypes:

  • tactical anti_triggers:
  • brainstorming
  • vague ideation response_profile: verbosity: low directive_strength: high abstraction_level: operational role: implementation scope: infrastructure output-format: code content-types:
  • code
  • guidance
  • config
  • do-dont related-skills: hardware-provisioning, networking, kernel-tuning, linux-security maturity: draft completeness: 90 exampleCount: 6

On-Premises Infrastructure Engineering

Infrastructure engineer managing physical servers, datacenter operations, and network-attached hardware for on-premises Linux environments — covering remote management (IPMI/iLO/iDRAC), PXE deployment, network storage (NFS/iSCSI/FC), multipath I/O, and datacenter physical operations.

TL;DR Checklist

  • Verify BMC/management interface accessibility via IPMI before any remote hardware operation
  • Configure multipath I/O for all SAN-attached storage with appropriate failover policy
  • Set up NFS mounts with hard/async or soft/sync options matching workload criticality
  • Test PXE boot workflow with a non-production host before mass deployment
  • Validate NTP/PTP synchronization across all on-prem systems for time-sensitive operations
  • Check thermal and power metrics (sensors, PDU) before any hardware replacement procedure
  • Document datacenter rack position, U slot, cable IDs, and BMC IP for every server

When to Use

Use this skill when:

  • Managing remote server hardware — You need to interact with IPMI, iLO, or iDRAC interfaces for power control, console access, or hardware diagnostics
  • Deploying OS at scale — You need to set up PXE boot infrastructure for network-based operating system installation across multiple bare-metal servers
  • Configuring network-attached storage — You need to set up NFS mounts, iSCSI targets/initiators, or Fibre Channel HBA configuration
  • Troubleshooting on-prem storage — SAN/NAS connectivity issues, multipath I/O problems, or HBA firmware/configuration
  • Datacenter physical operations — You need guidance on rack positioning, cable management, power/cooling considerations, or hardware replacement procedures
  • Hardware diagnostics at scale — You need to run ECC memory tests, thermal monitoring, or SMART analysis across many servers

When NOT to Use

Avoid this skill for:

  • Cloud instance provisioning — Use hardware-provisioning for cloud instances (AWS EC2, GCP, Azure VMs)
  • Virtual network configuration — Use networking for bond interfaces, VLANs, and nftables firewall rules
  • Kernel parameter tuning — Use kernel-tuning for TCP stack, filesystem, or I/O scheduler parameters
  • Software application development — This skill covers infrastructure, not application-level concerns

Use hardware-provisioning for RAID array configuration (local storage), SSD optimization, and initial workload-to-hardware matching. Use hardware-provisioning when the task is about selecting or sizing hardware before deployment.


Core Workflow

1. Verify Management Interface Accessibility

Before any remote hardware operation, confirm the BMC/management interface is reachable and responsive.

# Test IPMI connectivity to BMC
sudo ipmitool -I lanplus -H <BMC_IP> -U <username> -P '<password>' chassis power status

# If IPMI over LAN is blocked, try serial-over-LAN (SOL)
sudo ipmitool -I lanplus -H <BMC_IP> -U <username> -P '<password>' sol activate

# For iLO (HPE) — use the hponcfg or ipmitool with iLO-specific commands
sudo ipmitool -I lanplus -H <ILO_IP> -U admin chassis power status

# For iDRAC (Dell) — check iDRAC specific sensors and alerts
sudo ipmitool -I lanplus -H <IDRAC_IP> -U root sdr type "Temperature"
sudo ipmitool -I lanplus -H <IDRAC_IP> -U root event list

# Bulk check all BMCs from an inventory file
while IFS=',' read -r hostname bmc_ip bmc_user bmc_pass; do
    status=$(sudo ipmitool -I lanplus -H "$bmc_ip" -U "$bmc_user" -P "$bmc_pass" chassis power status 2>&1)
    echo "$hostname | BMC: $bmc_ip | Power: $status"
done < /opt/inventory/bmc_hosts.csv

Checkpoint: All target BMCs respond to basic IPMI commands. If a BMC is unreachable, verify network connectivity to the management VLAN (typically UDP port 623) and that the BMC is powered on.

2. Assess Hardware Health via BMC and Sensors

Gather a comprehensive hardware health picture before making changes or planning maintenance.

# Comprehensive hardware health check script
# Usage: ./hardware-health-check.sh [--bmc <ip> --user <u> --pass <p>] [--local]

set -euo pipefail

BMC_IP="${BMC_IP:-}"
BMC_USER="${BMC_USER:-}"
BMC_PASS="${BMC_PASS:-}"
MODE="${1:---local}"

check_local_health() {
    echo "=== Local Hardware Health ==="

    # CPU temperatures and fan speeds via lm-sensors
    echo "--- Thermal Sensors ---"
    sudo sensors 2>/dev/null || echo "lm-sensors not configured. Run: sudo sensors-detect"

    # SMART health for all disks
    echo "--- Disk SMART Health ---"
    for dev in /dev/sd* /dev/nvme*; do
        [[ -b "$dev" ]] || continue
        echo -n "$dev: "
        sudo smartctl -H "$dev" 2>/dev/null | grep -oP 'Overall-health.*?\K.*' || echo "N/A"
    done

    # ECC memory errors (if available)
    echo "--- Memory Error Counts ---"
    if command -v edac-util &>/dev/null; then
        edac-util -v 2>/dev/null || echo "EDAC not reporting errors"
    elif [[ -f /sys/devices/system/edac/mc/mc*/csrow*/ch*_ce_count ]]; then
        echo "Correctable errors:"
        cat /sys/devices/system/edac/mc/mc*/csrow/*/ch*_ce_count 2>/dev/null || echo "N/A"
    else
        echo "EDAC interface not available — ECC error monitoring requires kernel support"
    fi

    # PSU status via DMI
    echo "--- PSU Status ---"
    sudo ipmitool sdr type "Power Supply" 2>/dev/null || echo "IPMI not available for PSU check"
}

check_bmc_health() {
    echo "=== BMC-Managed Hardware Health ==="

    # SEL (System Event Log) — critical for failure forensics
    echo "--- System Event Log (last 20 entries) ---"
    sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" sel list 2>/dev/null | tail -20

    # FRU (Field Replaceable Unit) information
    echo "--- Field Replaceable Unit Info ---"
    sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" fru print 2>/dev/null || echo "FRU info unavailable"

    # Asset tag
    echo "--- Asset Information ---"
    sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" fru print "Asset Tag" 2>/dev/null || echo "Asset tag unavailable"

    # Power supply status
    echo "--- Power Supplies ---"
    sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" sdr type "Power Supply" 2>/dev/null

    # Thermal status
    echo "--- Thermal Readings ---"
    sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" sdr type "Temperature" 2>/dev/null
}

case "$MODE" in
    --local)   check_local_health ;;
    --bmc)     check_bmc_health ;;
    *)         check_local_health; check_bmc_health ;;
esac

Checkpoint: SEL logs are reviewed for recurring errors, SMART health is green for all disks, and thermal readings are within manufacturer specifications. Any anomalies are documented before proceeding.

3. Configure Network-Attached Storage

Set up the appropriate network storage protocol based on workload requirements.

# =============================================
# Pattern 1: NFS Mount Configuration
# =============================================

# NFS mount options — choose based on workload:
# hard,intr     — Retry forever on server failure (databases, filesystems)
# soft,timeo=N  — Return errors after timeout (non-critical, interactive)
# async         — Improve write performance (non-critical data)
# sync          — Guarantee writes are flushed (critical data)
# noatime       — Skip access time updates (performance)

# /etc/fstab entry for NFS
cat >> /etc/fstab << 'FSTAB'
# Production database storage — hard mount, noatime, sync
server1.example.com:/data/db     /mnt/db    nfs4  hard,intr,rsize=131072,wsize=131072,noatime,sync  0 0

# General file storage — hard mount, async, noatime
server1.example.com:/data/files  /mnt/files nfs4  hard,intr,rsize=131072,wsize=131072,noatime,async 0 0

# Temporary/scratch storage — soft mount, async, noatime
server2.example.com:/data/scratch /mnt/scratch nfs4 soft,timeo=50,retrans=2,noatime,async 0 0
FSTAB

# Verify mount
sudo mount -a
df -h /mnt/db /mnt/files /mnt/scratch

# NFS client performance tuning
cat > /etc/sysctl.d/99-nfs-client.conf << 'SYSCTL'
# NFS client socket buffer tuning
net.core.rmem_max = 16777216
net.core.rmem_default = 1048576
net.core.wmem_max = 16777216
net.core.wmem_default = 1048576
# NFS mount timeout tuning
fs.nfs.tcp_write_timeout_min = 1000
fs.nfs.tcp_read_timeout_list = 600 1000 2000 4000
SYSCTL
sudo sysctl -p /etc/sysctl.d/99-nfs-client.conf

# =============================================
# Pattern 2: iSCSI Initiator Configuration
# =============================================

# Install iSCSI initiator tools
sudo apt install -y open-iscsi iscsadm   # Debian/Ubuntu
sudo dnf install -y iscsi-initiator-utils # RHEL/CentOS/Alma

# Discover targets on the iSCSI network
iscsiadm -m discovery -t st -p 10.100.50.10:3260
iscsiadm -m discovery -t st -p 10.100.50.11:3260

# Log into discovered targets (persistent across reboots)
iscsiadm -m node -T iqn.2001-04.com.example:storage.disk1 --login

# Set initiator name in config
cat > /etc/iscsi/initiatorname.iscsi << 'INITIATOR'
InitiatorName=iqn.2025-01.local:hostname.example.com
INITIATOR

# Configure CHAP authentication (required by most SAN arrays)
cat > /etc/iscsi/iscsid.conf << 'ISCSID'
# CHAP authentication to target
node.session.auth.authmethod = CHAP
node.session.auth.username = initiator_user
node.session.auth.password = secret_password

# Enable multipath-friendly path detection
node.conn[0].timeo.noop_out_interval = 5
node.conn[0].timeo.noop_out_timeout = 5
node.conn[0].timeo.initial_r2t_time = 0
ISCSID

# =============================================
# Pattern 3: Multipath I/O Configuration
# =============================================

# Install and configure multipath-tools
sudo apt install -y multipath-tools   # Debian/Ubuntu
sudo dnf install -y device-mapper-multipath  # RHEL/CentOS

# Start multipath service
sudo systemctl enable --now multipathd

# Configure multipath
cat > /etc/multipath.conf << 'MULTIPATH'
defaults {
    user_friendly_names yes
    find_multipaths yes
    max_fds 8192
}

devices {
    device {
        vendor                  "DELL"
        product                 "MD38xx"
        path_checker            tur
        path_selector           "service-time 0"
        hardware_handler        "1 alua"
        failback                immediate
        no_path_retry           18
        rr_weight               priorities
        features                "1 queue_if_no_path"
        prio                    alua
    }
    device {
        vendor                  "HPE"
        product                 "P6000"
        path_checker            tur
        path_selector           "service-time 0"
        hardware_handler        "1 alua"
        failback                immediate
        no_path_retry           18
        prio                    alua
    }
    device {
        vendor                  "NETAPP"
        product                 "LUN"
        path_checker            tur
        path_selector           "service-time 0"
        hardware_handler        "1 alua"
        failback                immediate
        no_path_retry           18
        prio                    alua
    }
}

blacklist {
    devnode "^sda"          # Exclude local OS disk
    devnode "^nvme[0-9]n1"  # Exclude local NVMe
}
MULTIPATH

# Reload and verify multipath
sudo multipath -r
sudo multipath -ll

# Expected output shows multiple paths per device with failover
# dm-0 (3600601603e1d2800d6e9f0a1b3c4d5e6) dm-0 DEVEL,MD38xx
# size=2.0T features='1 queue_if_no_path' hwhandler='1 alua'
# \_ round-robin 0 [prio=200][active]
#   \_ 3:0:0:0 sdb 8:16  [ready][running]
#   \_ 4:0:0:0 sdc 8:32  [ready][running]

Checkpoint: All storage paths are visible via multipath -ll, the device is marked active, and failover paths are ready. For NFS, verify the mount with mount | grep nfs and test read/write operations.

4. Configure PXE Boot Infrastructure

Set up network-based OS deployment for bare-metal server provisioning.

# =============================================
# PXE Boot Infrastructure Setup
# =============================================
# Components needed:
#   - DHCP server (isc-dhcp-server or dnsmasq)
#   - TFTP server (tftpd-hpa or dnsmasq)
#   - HTTP/HTTPS server (nginx/apache) for install media
#   - Kickstart/PXE config files

# --- Step 1: DHCP Configuration ---
cat > /etc/dhcp/dhcpd.conf << 'DHCPD'
# PXE boot DHCP configuration
authoritative;

# Option for PXE client to find TFTP server
option tftp-server-name "10.0.1.20";
option bootfile-name "pxelinux.0";

subnet 10.0.1.0 netmask 255.255.255.0 {
    range 10.0.1.100 10.0.1.200;
    option routers 10.0.1.1;
    option domain-name-servers 10.0.1.53, 8.8.8.8;

    # PXE boot group — all hosts
    next-server 10.0.1.20;

    # Per-host PXE entries (optional, for specific provisioning)
    # host server-rack1a {
    #     hardware ethernet 00:1a:2b:3c:4d:5e;
    #     fixed-address 10.0.1.10;
    #     option host-name "server-rack1a";
    # }
}
DHCPD

# --- Step 2: TFTP Server Setup ---
sudo apt install -y tftpd-hpa   # Debian/Ubuntu
sudo dnf install -y tftp-server  # RHEL/CentOS

# Configure tftpd-hpa
sudo tee /etc/default/tftpd-hpa > /dev/null << 'TFTPD'
TFTP_USERNAME="tftp"
TFTP_DIRECTORY="/var/lib/tftpboot"
TFTP_ADDRESS="0.0.0.0:69"
TFTP_OPTIONS="--secure --listen --map-file=/etc/tftpd-map"
TFTPD

# --- Step 3: Deploy PXE Boot Files ---
sudo mkdir -p /var/lib/tftpboot/{pxelinux.cfg,EFI/boot,kernel,initrd}

# Copy PXE boot loader (Syslinux)
sudo cp /usr/lib/syslinux/modules/bios/pxelinux.0 /var/lib/tftpboot/
sudo cp /usr/lib/syslinux/modules/bios/libutil.c32 /var/lib/tftpboot/
# UEFI boot
sudo cp /usr/lib/shim/shimx64.efi.signed /var/lib/tftpboot/EFI/boot/bootx64.efi 2>/dev/null || \
    sudo cp /usr/lib/shim/shimx64.efi /var/lib/tftpboot/EFI/boot/bootx64.efi

# Copy kernel and initrd for the target OS
sudo cp /var/www/html/ubuntu/22.04/casper/vmlinuz /var/lib/tftpboot/kernel/vmlinuz-ubuntu2204
sudo cp /var/www/html/ubuntu/22.04/casper/initrd.lz /var/lib/tftpboot/initrd/initrd-ubuntu2204.lz

# PXE boot menu configuration
cat > /var/lib/tftpboot/pxelinux.cfg/default << 'PXE'
DEFAULT menu.c32
PROMPT 0
TIMEOUT 300
ONTIMEOUT ubuntu-local

LABEL ubuntu-local
    MENU LABEL ^Local Boot
    LOCALBOOT 0

LABEL ubuntu-2204-ks
    MENU LABEL Ubuntu 22.04 ^Kickstart (Automated)
    KERNEL /kernel/vmlinuz-ubuntu2204
    APPEND initrd=/initrd/initrd-ubuntu2204.lz auto=true priority=critical \
        url=http://10.0.1.20/ks/ubuntuks.cfg \
        ip=dhcp netcfg/choose_interface=auto

LABEL ubuntu-2204-manual
    MENU LABEL Ubuntu 22.04 ^Manual Install
    KERNEL /kernel/vmlinuz-ubuntu2204
    APPEND initrd=/initrd/initrd-ubuntu2204.lz auto=true priority=high \
        ip=dhcp netcfg/choose_interface=auto

LABEL memtest
    MENU LABEL ^Memory Test (Memtest86+)
    KERNEL /kernel/memtest
PXE

# --- Step 4: Kickstart Configuration (RHEL/Alma) ---
cat > /var/www/html/ks/almalinux.cfg << 'KICKSTART'
# Auto-provisioned AlmaLinux 9
install
text
keyboard 'us'
lang en_US.UTF-8
network --bootproto=dhcp --device=eth0 --onboot=on --hostname=$HOSTNAME
rootpw --iscrypted <hashed_root_password>
timezone UTC --isUtc
bootloader --location=mbr --driveorder=sda --append="crashkernel=auto"

# Disk layout — wipe all disks
zerombr
clearpart --all --initlabel
part /boot --fstype=xfs --size=1024 --ondisk=sda
part / --fstype=xfs --size=100 --grow --ondisk=sda

# Firewall configuration
firewall --enabled --ssh

# Reboot after installation
reboot --exit

%packages
@core
@hardware-monitoring
smartmontools
ipmitool
net-tools
wget
curl
%end

%post
# Configure NTP
yum install -y chrony
systemctl enable --now chronyd

# Enable IPMI
systemctl enable --now ipmi

# Install monitoring agent
wget -O /usr/local/bin/node-exporter https://example.com/node_exporter
chmod +x /usr/local/bin/node-exporter

# Set up SSH authorized keys from config server
curl -s http://10.0.1.20/keys/$HOSTNAME.pub >> /root/.ssh/authorized_keys

# Update hostname
hostnamectl set-hostname $HOSTNAME
%end
KICKSTART

Checkpoint: PXE boot is verified by booting a test client. Confirm DHCP assigns the correct bootfile, TFTP serves the boot files, and the kickstart installation completes without manual intervention.

5. Configure Network Time Synchronization

Set up NTP or PTP for precision timing across on-prem infrastructure.

# =============================================
# Pattern 1: NTP with Chrony (recommended)
# =============================================

sudo apt install -y chrony       # Debian/Ubuntu
sudo dnf install -y chrony       # RHEL/CentOS

# Chrony configuration for on-prem datacenter
cat > /etc/chrony/chrony.conf << 'CHRONY'
# Datacenter NTP configuration
# Stratum 1: Direct GPS or PTP grandmaster
# Stratum 2: Local datacenter NTP servers
# Stratum 3+: All other servers

# External time sources (stratum 1)
server time.cloudflare.com iburst minpoll 4 maxpoll 6
server pool.ntp.org iburst minpoll 4 maxpoll 6

# Local stratum 1 reference (GPS or hardware clock)
# server 127.127.28.1 # GPS reference clock
# fudge 127.127.28.1 refid GPS

# Local NTP servers for the datacenter (stratum 2)
server ntp1.internal.corp iburst prefer
server ntp2.internal.corp iburst

# Allow local clients to sync from this server (if acting as NTP server)
# Allow subnet only — never open to the world
allow 10.0.0.0/8
allow 172.16.0.0/12
allow 192.168.0.0/16
# deny 0.0.0.0/0  # Explicit deny all others

# Local clock as fallback (when no external sources available)
local stratum 10
leapsectz right/UTC

# Record clock drift for analysis
driftfile /var/lib/chrony/drift

# Log every 30 minutes
logdir /var/log/chrony
log measurements statistics tracking

# Key tracking
keyfile /etc/chrony/chrony.keys

# Clock discipline
makestep 1.0 3
rtcsync
CHRONY

sudo systemctl enable --now chronyd

# Verify synchronization
chronyc tracking
chronyc sources -v

# =============================================
# Pattern 2: PTP (Precision Time Protocol) for sub-microsecond precision
# =============================================

# PTP is required for: financial trading, distributed databases, HPC clusters
# Requires: PTP-capable NIC, PTP grandmaster, linuxptp package

sudo apt install -y linuxptp   # Debian/Ubuntu
sudo dnf install -y linuxptp   # RHEL/CentOS

# PTP configuration — select the PTP-capable interface
# Check if NIC supports PTP
ethtool -T eth1 | grep "SOF_TIMESTAMPING"

# Configure phc2sys (hardware timestamping)
cat > /etc/ptp4l.conf << 'PTP'
[global]
    default_ds.port_state_change_threshold 5
    delay_mechanism E2E
    time_stamping hardware
    log_announce_interval -3
    announce_receipt_timeout 4
    sync_receipt_timeout 3
    announce_interval -3
    sync_interval -3
    parentstats_mean_offset_threshold 10000000
    assume_two_step 0

[eth1]
    # PTP-enabled interface
    delay_filter 2
PTP

# Start PTP clock
sudo ptp4l -i eth1 -f /etc/ptp4l.conf &
sudo phc2sys -a -s eth1

# Verify PTP sync
sudo phc_ctl eth1 getcrosstimestamp
sudo ptptime eth1

Checkpoint: chronyc tracking shows locked to a stratum 1 or 2 source with offset in acceptable range (< 1ms for NTP, < 1μs for PTP). chronyc sources -v shows at least one reachable source marked with *.

6. Hardware Replacement Procedure

When a component fails, follow a structured replacement procedure to minimize downtime and data loss.

#!/bin/bash
# Hardware replacement procedure — for use during maintenance windows
# Usage: ./hardware-replace.sh <component> <server> [--dry-run]
# Components: disk, memory, psu, hba, fan, cpu

set -euo pipefail

COMPONENT="${1:-}"
SERVER="${2:-}"
DRY_RUN="${3:---live}"

if [[ -z "$COMPONENT" || -z "$SERVER" ]]; then
    echo "Usage: $0 <component> <server> [--dry-run]"
    echo "Components: disk, memory, psu, hba, fan, cpu"
    exit 1
fi

echo "=== Hardware Replacement Procedure ==="
echo "Component: $COMPONENT"
echo "Server:    $SERVER"
echo "Mode:      $DRY_RUN"
echo "=== "

# Pre-replacement checks
echo ""
echo "1. Pre-Replacement Health Check"
echo "---"

if [[ "$COMPONENT" == "disk" ]]; then
    # Identify the failing disk
    echo "Checking SMART status on all disks..."
    for dev in /dev/sd* /dev/nvme*; do
        [[ -b "$dev" ]] || continue
        health=$(sudo smartctl -H "$dev" 2>/dev/null | grep -oP 'Overall-health.*?\K.*' || echo "unknown")
        temp=$(sudo smartctl -A "$dev" 2>/dev/null | grep -i 'temperature' | head -1 | awk '{print $10}')
        reallocated=$(sudo smartctl -A "$dev" 2>/dev/null | grep -i 'Reallocated_Sector' | awk '{print $10}')
        echo "  $dev: health=$health temp=${temp}C reallocated=$reallocated"
    done

    # Identify disk in RAID (if applicable)
    if command -v mdadm &>/dev/null; then
        echo ""
        echo "RAID status:"
        mdadm --detail --scan 2>/dev/null | while read -r line; do
            echo "  $line"
        done
    fi
    if command -v multipath &>/dev/null; then
        echo ""
        echo "Multipath devices:"
        multipath -ll 2>/dev/null | head -20
    fi
fi

if [[ "$COMPONENT" == "psu" ]]; then
    echo "Checking power supply status via IPMI..."
    sudo ipmitool sdr type "Power Supply" 2>/dev/null || echo "IPMI unavailable"
    sudo ipmitool sdr type "Voltage" 2>/dev/null | grep -i "psu\|power" || echo "No PSU voltage sensors found"
fi

if [[ "$COMPONENT" == "memory" ]]; then
    echo "Checking memory error counts..."
    if command -v edac-util &>/dev/null; then
        edac-util -v 2>/dev/null || echo "No EDAC errors reported"
    fi
    dmesg | grep -iE 'mem|e?cc|uncorrectable' | tail -20 || echo "No memory errors in dmesg"
fi

# Pre-replacement data backup
echo ""
echo "2. Verify Data Backup Status"
echo "---"
echo "  [!] Ensure backups are current before replacing any component"
echo "  [!] For disk replacement, verify RAID sync is complete"
echo "  [!] For PSU replacement, confirm UPS is connected and functional"

# Component-specific steps
echo ""
echo "3. Component-Specific Replacement Steps"
echo "---"

case "$COMPONENT" in
    disk)
        echo "   a. Identify the failing disk: /dev/sdX"
        echo "   b. Mark disk as failed in RAID:   mdadm /dev/md0 --fail /dev/sdX"
        echo "   c. Remove disk from RAID:         mdadm /dev/md0 --remove /dev/sdX"
        echo "   d. Physically replace disk (hot-swap capable)"
        echo "   e. Add new disk:                    mdadm /dev/md0 --add /dev/sdX"
        echo "   f. Monitor rebuild:                  watch cat /proc/mdstat"
        echo "   g. Verify SMART on new disk:         smartctl -a /dev/sdX"
        ;;
    psu)
        echo "   a. Verify UPS is connected and functional"
        echo "   b. Check current PSU power draw:    ipmitool sdr type 'Power Supply'"
        echo "   c. Power down if non-hot-swap:       ipmitool power off"
        echo "   d. Replace PSU (observe ESD precautions)"
        echo "   e. Power on:                          ipmitool power on"
        echo "   f. Verify both PSUs are reporting:    ipmitool sdr type 'Power Supply'"
        ;;
    memory)
        echo "   a. Identify failed DIMM slot via BMC: ipmitool sdr type Memory"
        echo "   b. Power down the server"
        echo "   c. Replace DIMM (observe ESD precautions, match speed/capacity)"
        echo "   d. Power on and verify:               dmidecode -t memory"
        echo "   e. Run memtest86+ if ECC errors persist"
        ;;
    hba)
        echo "   a. Identify HBA and current paths:    multipath -ll"
        echo "   b. Stop multipath:                     systemctl stop multipathd"
        echo "   c. Detach all paths:                   multipath -f all"
        echo "   d. Power down if non-hot-swap HBA"
        echo "   e. Replace HBA card"
        echo "   f. Power on, reload multipath:         systemctl start multipathd"
        echo "   g. Verify paths:                       multipath -ll"
        echo "   h. Update firmware if needed:          hpssacli ctrl all show config"
        ;;
    fan)
        echo "   a. Identify failed fan via BMC:        ipmitool sdr type 'Fan'"
        echo "   b. Hot-swap fan if supported (server must remain powered)"
        echo "   c. Verify fan speed recovery:          ipmitool sdr type 'Fan'"
        echo "   d. Monitor temperature:                ipmitool sdr type 'Temperature'"
        ;;
    cpu)
        echo "   a. CPU replacement is a major operation"
        echo "   b. Power down and unplug server"
        echo "   c. Discharge residual power (hold power button 30s)"
        echo "   d. Replace CPU (match socket, TDP, stepping)"
        echo "   e. Apply fresh thermal paste"
        echo "   f. Power on and verify:                 lscpu"
        echo "   g. Run stress test:                     stress-ng --cpu 0"
        ;;
    *)
        echo "  Unknown component: $COMPONENT"
        echo "  Valid components: disk, memory, psu, hba, fan, cpu"
        exit 1
        ;;
esac

if [[ "$DRY_RUN" == "--dry-run" ]]; then
    echo ""
    echo "=== DRY RUN COMPLETE — No changes made ==="
else
    echo ""
    echo "=== Execute the above steps in your maintenance window ==="
    echo "=== Ensure rollback procedures are documented ==="
fi

Checkpoint: After replacement, run a full hardware health check (step 2) to confirm the new component is recognized, reporting normal metrics, and no error messages appear in SEL or dmesg.


Implementation Patterns

Pattern 1: IPMI Remote Power Cycle (BAD vs. GOOD)

# ❌ BAD: Blindly powering cycle without checking health first
ipmitool -I lanplus -H $BMC_IP -U admin chassis power cycle
#
# Problems:
# - No health check before the power cycle
# - No confirmation the right BMC is targeted
# - No audit trail of the action
# - Could power cycle the wrong server in a large fleet

# ✅ GOOD: Safe remote power management with health checks and audit trail
#!/usr/bin/env bash
set -euo pipefail

BMC_IP="${1:?Usage: $0 <bmc_ip> <action>}"
ACTION="${2:-status}"
AUDIT_LOG="/var/log/ipmi-actions.log"

# Validate BMC IP format
if ! [[ "$BMC_IP" =~ ^[0-9]+\.[0-9]+\.[0-9]+\.[0-9]+$ ]]; then
    echo "Error: Invalid BMC IP: $BMC_IP" >&2
    exit 1
fi

# Check BMC connectivity before acting
echo "Checking BMC connectivity..."
if ! sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" sdr 2>/dev/null | head -1 > /dev/null; then
    echo "Error: BMC at $BMC_IP is unreachable" >&2
    exit 1
fi

# Get hostname from inventory (correlate BMC to server)
get_hostname() {
    local bmc_ip="$1"
    grep "^$bmc_ip," /opt/inventory/bmc_hosts.csv | cut -d',' -f1 || echo "unknown-$bmc_ip"
}

HOSTNAME=$(get_hostname "$BMC_IP")
TIMESTAMP=$(date -Iseconds)

case "$ACTION" in
    status)
        echo "Power status of $HOSTNAME ($BMC_IP):"
        sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" chassis power status
        ;;
    on)
        echo "Powering ON $HOSTNAME..."
        sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" chassis power on
        ;;
    off)
        echo "Gracefully shutting down $HOSTNAME..."
        # Prefer OS-level shutdown first (graceful)
        ssh -o ConnectTimeout=5 root@"$HOSTNAME" 'poweroff' 2>/dev/null || {
            echo "SSH shutdown failed. Using BMC power off."
            sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" chassis power off
        }
        ;;
    cycle)
        echo "Power cycling $HOSTNAME..."
        sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" chassis power off
        sleep 5
        sudo ipmitool -I lanplus -H "$BMC_IP" -U "$BMC_USER" -P "$BMC_PASS" chassis power on
        ;;
    *)
        echo "Usage: $0 <bmc_ip> {status|on|off|cycle}"
        exit 1
        ;;
esac

# Audit log entry
echo "$TIMESTAMP | $HOSTNAME | $BMC_IP | $ACTION | $(whoami)" >> "$AUDIT_LOG"

Pattern 2: PXE Boot Health Check Before Mass Deployment

#!/usr/bin/env bash
# Validate PXE infrastructure before deploying to production fleet
set -euo pipefail

TFTP_DIR="/var/lib/tftpboot"
DHCPD_CONF="/etc/dhcp/dhcpd.conf"
HTTP_ROOT="/var/www/html"

echo "=== PXE Infrastructure Pre-Flight Check ==="
PASS=0
FAIL=0

check() {
    local desc="$1"
    local result="$2"
    if [[ "$result" == "0" ]]; then
        echo "  [PASS] $desc"
        ((PASS++))
    else
        echo "  [FAIL] $desc"
        ((FAIL++))
    fi
}

# Check DHCP service
systemctl is-active --quiet dhcpd 2>/dev/null || systemctl is-active --quiet isc-dhcp-server 2>/dev/null
check "DHCP service is running" $?

# Check TFTP directory exists and has boot files
[[ -d "$TFTP_DIR" ]] && [[ -f "$TFTP_DIR/pxelinux.0" ]]
check "TFTP directory exists with pxelinux.0" $?

# Check PXE menu exists
[[ -f "$TFTP_DIR/pxelinux.cfg/default" ]]
check "PXE boot menu configuration exists" $?

# Check kernel and initrd are present
[[ -f "$TFTP_DIR/kernel/vmlinuz"* ]] && [[ -f "$TFTP_DIR/initrd/initrd"* ]]
check "Kernel and initrd files present" $?

# Check HTTP/HTTPS serve of kickstart files
curl -s -o /dev/null -w "%{http_code}" "http://localhost${HTTP_ROOT}" | grep -q "^200" || curl -s -o /dev/null -w "%{http_code}" "http://127.0.0.1${HTTP_ROOT}" | grep -q "^200"
check "Kickstart files are accessible via HTTP" $?

# Check DHCP configuration syntax
dhcpd -t 2>/dev/null
check "DHCP configuration syntax is valid" $?

# Check TFTP server is listening
ss -ulnp | grep -q ':69'
check "TFTP server is listening on UDP 69" $?

echo ""
echo "Results: $PASS passed, $FAIL failed"

if [[ "$FAIL" -gt 0 ]]; then
    echo "Fix failures before PXE deployment!"
    exit 1
fi
echo "PXE infrastructure is ready for deployment."

Pattern 3: Bulk BMC Health Check Across Fleet

#!/usr/bin/env bash
# Check health of all BMCs in the datacenter
# Inventory CSV format: hostname,bmc_ip,bmc_user,bmc_pass,location,rack
set -euo pipefail

INVENTORY="/opt/inventory/bmc_hosts.csv"
RESULTS="/tmp/bmc-health-$(date +%Y%m%d-%H%M%S).csv"
TIMEOUT=5

echo "hostname,bmc_ip,status,power,alert_count,last_check" > "$RESULTS"

if [[ ! -f "$INVENTORY" ]]; then
    echo "Error: Inventory file not found: $INVENTORY" >&2
    exit 1
fi

# Skip header line
tail -n +2 "$INVENTORY" | while IFS=',' read -r hostname bmc_ip bmc_user bmc_pass location rack; do
    TIMESTAMP=$(date -Iseconds)

    # Test BMC connectivity
    if ! sudo ipmitool -I lanplus -H "$bmc_ip" -U "$bmc_user" -P "$bmc_pass" -t "$TIMEOUT" chassis power status &>/dev/null; then
        echo "$hostname,$bmc_ip,unreachable,-,-,$TIMESTAMP" >> "$RESULTS"
        continue
    fi

    # Get power status
    power=$(sudo ipmitool -I lanplus -H "$bmc_ip" -U "$bmc_user" -P "$bmc_pass" chassis power status 2>/dev/null | grep -oP 'Chassis Power.*?\K.*' || echo "unknown")

    # Count recent SEL alerts (last 24h)
    alert_count=$(sudo ipmitool -I lanplus -H "$bmc_ip" -U "$bmc_user" -P "$bmc_pass" sel elist 2>/dev/null | wc -l || echo "0")

    # Determine status
    if [[ "$alert_count" -gt 10 ]]; then
        status="degraded"
    elif [[ "$power" == "on" ]]; then
        status="healthy"
    else
        status="powered-off"
    fi

    echo "$hostname,$bmc_ip,$status,$power,$alert_count,$TIMESTAMP" >> "$RESULTS"
done

echo ""
echo "=== BMC Health Summary ==="
echo "Results saved to: $RESULTS"
echo ""
cat "$RESULTS"

Constraints

MUST DO

  • MUST verify BMC connectivity and power status before any remote power operation — never assume the server is in the expected state
  • MUST use multipath-tools with ALUA path priority for all iSCSI and Fibre Channel SAN storage — single-path storage is a single point of failure
  • MUST configure NFS mounts with hard option for database and filesystem workloads — soft mounts can cause data corruption if the server temporarily goes unreachable
  • MUST test PXE boot with a non-production host before any mass deployment — PXE issues can lock out entire server fleets
  • MUST document datacenter rack position, U slot, cable IDs, and BMC IP for every server in an asset inventory — physical operations require this information
  • MUST use set -euo pipefail in all shell scripts that interact with hardware — unexpected failures can cause data loss or hardware damage
  • MUST maintain NTP synchronization across all on-prem systems — distributed systems with unsynchronized clocks produce unreliable logs, metrics, and transaction ordering
  • MUST review SEL (System Event Log) before any hardware replacement — the SEL often reveals the root cause of the failure

MUST NOT DO

  • MUST NOT power cycle a server without first attempting a graceful OS-level shutdown via SSH or BMC SOL — abrupt power loss can corrupt filesystems and databases
  • MUST NOT replace a disk in a RAID array without verifying backup integrity first — if the array fails during rebuild, you lose everything
  • MUST NOT expose iSCSI or NFS to untrusted networks without authentication (CHAP for iSCSI, IP-based access controls for NFS)
  • MUST NOT disable multipath failover or set no_path_retry to off — this creates immediate I/O failure on any path interruption
  • MUST NOT rely on BMC-only management — always maintain console access (serial/IPMI SOL) as a fallback when IPMI LAN is unavailable
  • MUST NOT configure PXE boot without validating DHCP, TFTP, and HTTP services first — a broken PXE infrastructure can prevent all servers from booting
  • MUST NOT ignore thermal warnings before hardware maintenance — high temperatures indicate cooling failures that could worsen during component replacement

Related Skills

SkillPurpose
hardware-provisioningInitial hardware sizing, RAID configuration, and SSD optimization for the provisioned servers
networkingBond interfaces, VLANs, and firewall rules that complement on-prem network storage and PXE infrastructure
kernel-tuningTune I/O scheduler, TCP, and filesystem parameters for multipath and NFS performance
linux-securityHarden the server post-provisioning: SSH hardening, file permissions, and audit logging