Use when checking synthesis and characterization rigor for a Journal of the American Chemical Society (JACS) manuscript — purity, NMR/HRMS/IR/UV-vis, elemental analysis or HPLC, single-crystal X-ray/CCDC, and catalysis controls/mechanism/kinetics. Audits experimental rigor — it does not write narrative or polish prose.
Independent GitHub snapshot · Automated classification · Original documentation governs
name: jacs-methods
description: Use when checking synthesis and characterization rigor for a Journal of the American Chemical Society (JACS) manuscript — purity, NMR/HRMS/IR/UV-vis, elemental analysis or HPLC, single-crystal X-ray/CCDC, and catalysis controls/mechanism/kinetics. Audits experimental rigor — it does not write narrative or polish prose.
Synthesis and Characterization Rigor (jacs-methods)
When to trigger
New compounds are reported and you must confirm full characterization
A reviewer could ask "is this compound pure?" or "where is the X-ray?"
A mechanism is claimed but only proposed, not tested
Catalysis scope/selectivity is reported and controls are unclear
Characterization rigor by claim type
JACS requires that claims are fully supported by characterization data and
appropriate controls. Match the data package to what you assert.
Audit each block for: mass and percentage yield, physical state, every
nucleus relevant to the structure, coupling constants on diagnostic multiplets,
calcd/found within instrument tolerance, and the full chiral method — not just
the er value.
Referee rigor probes (pre-empt them)
"Compound x shows a peak at δ 1.56 — water or impurity?" → annotate
residual-solvent peaks in the SI spectra copies before a referee circles them.
"Yields are single runs?" → state replicate counts for headline entries; give
an average with the spread for the model reaction.
"Could adventitious metal catalyze this?" → for base-metal or 'metal-free'
claims, report reagent lot ICP data or a deliberate trace-metal spike control.
"The cycle shows Ni(I)/Ni(III) — where is the evidence?" → every oxidation
state drawn in a mechanism figure must trace to an EPR/UV-vis/electrochemical
or kinetic observation, or be labeled as proposed.
Reproducibility test
Could an independent chemist reproduce each yield, ee, and spectrum from the
written procedure alone? If not, the procedure is incomplete — fix before figures.
The strongest SI procedures also state how the compound was purified (column
eluent, distillation T/p), on what scale the reaction was validated, and any
setup detail on which the outcome hinges (drying of solvent, exclusion of light,
stirring rate for biphasic mixtures).
Anti-patterns
New compound reported with no purity criterion (no EA, no HPLC, no clean ¹³C)
"Pure by NMR" as the only purity statement for a key compound
Mechanism drawn as a cycle with no kinetic/labeling/control support
Crystal structure shown but CIF not deposited / no CCDC number
Scope table that hides failed substrates; idealized yields not reproducible
HRMS reported without ionization mode or calcd/found pair